EN – 7
DRAINING FUEL SYSTEM
1.
Move unit to an open, well-ventilated area with no
flames or sparks.
2.
Remove cap from fuel tank and siphon fuel into a
clean, clearly-marked gasoline container.
3.
Reinstall fuel tank cap and tighten.
4.
Start engine to burn remaining fuel in fuel system and
leave engine running until it “runs dry” and stops.
Refer to Operator’s Manual for engine start procedure.
5.
Stop engine, remove key and close fuel valve.
SERVICE POSITION
NOTICE:
NEVER store unit in service position.
SEPARATE HOUSING FROM FRAME
Remove Auger Housing
IMPORTANT:
Save all hardware for reinstallation.
1.
Stop engine, remove key and wait for all moving parts
to stop and for hot parts to cool.
2.
Disconnect spark plug wire from engine.
3.
Remove cable hanger from chute rotation rod.
Remove hardware retaining chute gear cover and
remove cover.
5.
Remove spring clip from chute rotation rod and
remove rod from chute gear socket.
WARNING:
AVOID INJURY. Before placing unit
in service position, drain fuel from tank and fuel
system. See
Make sure unit is secure and will not tip.
Figure 2