![ARI D-040L Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/ari/d-040l/d-040l_installation-operation-and-maintenance_2969548018.webp)
18
IOM D-040L
2”
5.3.4.
Reassembling the Operating Valve
Dip the head end of the Rolling Seal into the liquid soap solution [1]
Reassemble the Operating Valve by inserting the loose end of the Rolling Seal into its designated groove in the Body,
making sure that the end of the seal and the insertion are in the direction of the arrows [2], [3].
1
2