8 Operation on an SHDSL Access
ARGUS 145
PLUS
123
Connection successfully setup
Once the connection has been setup (“Sync / L1” LED on constantly and a green LED will
be shown in the display), the ARGUS will determine and display the SHDSL connection
parameters. After the ARGUS has synchronized, please leave it connected to the SHDSL
access for at least another 20 seconds since the SHDSL connection parameters supplied
by the DSLAM cannot be stored in the ARGUS until this period of time has elapsed.
ARGUS – State display.
Display:
If the current data rates are equal to those
set (see page
113), the ARGUS will
display "OK“, otherwise it will display
"FAIL“.
The ARGUS displays the SHDSL line's
connection parameters for both the
remote side (R) and the central office side
(C) (see "SHDSL Transmission Line" in
the illustration below) as well as for each
available line segment (see the illustration
below). To receive the remote end's
parameters, set "EOC usage“ to "on“ see
page 113.
-
Access and SHDSL mode
-
Default (preset) profile
-
Spectrum / Clock (sync = synchronous)
-
Status (Data)
<Edit>
The preset profile will be displayed
(in this example, Profile 1). The
SHDSL access parameters are
write-protected, other parameters
can be edited here.
<Menu>
Open the Main menu.
<Stop>
Clear the SHDSL connection down.
Scroll through the parameters
Display:
n/a
Not available
n/u
Not used
n/r
Not received