![Argus 145 Plus Скачать руководство пользователя страница 113](http://html.mh-extra.com/html/argus/145-plus/145-plus_manual_2969457113.webp)
8 Operation on an SHDSL Access
ARGUS 145
PLUS
113
Settings:
Explanation:
Access parameters
Phys. parameters:
SHDSL:
Access parameters for the SHDSL connection
Spectrum
For Region 1 (e.g. North America):
Annex A SHDSL and Annex F SHDSL.bis
For Region 2 (e.g. Europe):
Annex B SHDSL and Annex G SHDSL.bis
Default setting:
depends on country
Data rate
Setting the data rate in kbit/s
For SHDSL:
- Range: 192 kbit/s to 2304 kbit/s
- Default setting:
*
(automatic)
For SHDSL.bis
- Range 768 kbit/s to 5696 kbit/s
- Default setting:
*
(automatic)
Power back off
Reduces the signal strength of the transmission to the remote end; the
strength is set to the maximum.
Range: 0 dB to 30 dB
Default setting:
0 dB
EOC usage
Using the EOC (Embedded Operations Channel), it is possible to
exchange among other things connection information.
Default setting:
on (passive)
off:
No requests and answers will be sent to the remote
end.
on (passive):
No display of the remote end's parameter, since it only
responds to requests.
on (active):
Display the performance parameters of the local (own)
and remote ends, if the remote end supports the own
request.