background image

4  USER INFORMATION:

 

 

3.4 Installing wired detector and its zone setting:

 

 

 

 

4.1 Methods of Arming and Disarming

 

Arming: Arming is used to arm the whole Alarm system. All detectors in the zones within 

the protected area must be closed(not in alarm)in order for you to arm the system successfully.

 

 

Part Arming:  Part Arming is  used to  partially Arm your  System by arming the  selected 

zones in the protected area,which permits persons to remain in the premises while the system 

is Part Armed.

 

 

Disarming:Disarms the system and deactivates any alarms in progress and disarms all the 

zones other than the 24 hour Zones.

 

 

 

4.1.1. Arming and Disarming through the Keypad on the panel

 

How To Arm: Pressing the ARM key on the keypad to arm the system.

 

How To Part Arm:  Pressing the  ARM  Key on the Keypad for  2 seconds to Part Arm  the 

system.

 

How To Disarm: Press the DISARM key on the keypad then using the Keypad again enter 

the pre-programmed 6 digit PIN code to complete the disarming operating.

 

 

 
 

4.1.2. Arming and Disarming through the Key Fob Remote Device

 

 

How To Arm: Press the Arm key on the Key Fob to Arm the system.

 

How To Part Arm: Pressing the Part Arm key on the key Fob to Part Arm the system. 

How To Disarm: Press the DISARM key on the key Fob to Dis-Arm the system.

 

Various  wired  detector  could be connected  to the panel  via the N.C terminal.  Seven  wired 

connection  in all, and  the terminals   for  connection  are  1\2\3\4  \5\6\7,  GND  is the  common 

terminal.

 

Zone setting: 

After  connecting  well the wired  detector  to the panel,press  the PROG  key 

on the keypad,  a series  of ----- appear  on the LCD.  Enter the PIN code or press the Disarm  key 

on a registered  key fob and the word  'Sensor'  will appear  on the LCD.Trigger  the detector  you 

wish to register,  the panel  will receive  the detectors  code and the word  'CODE'  will appear  on 

the LCD.Pressing  a numeric  key 1 to 8 on the keypad  will select  the zone you wish to allocate 

the detector.  e.g. Pressing  No 3 on the keypad  will allocate  the detector  to Zone  3. The control 

panel  will then automatically  allocate  the detector  with the next available  detector  number  in 

that Zone.  So, if there are no detectors  allocated  in Zone  3 the control  panel  will allocate  it as 

detector  No 1 and the next detector  to be registered  in Zone  3 will be allocated  detector  No 2 

etc. To complete  and save the information  press PROG  key.

 

 

( Also you could   first fix two  wires  to terminal   1.2.3.4.5.6  or 7 and GND,   then connect 

them  together.  Disconnect  them  when  triggered.  It is ok then  to replace  with  a wired  detector 

after registration.)

 

 
 

3.5 Checking Registration

 

 

Checking  key fob and sensor  registration:press  the # key on  the keypad,the  LCD  displays 

word TEST, Activate  a detector,  a bleep  noise  will be heard confirming  the control  panel   has 

received  the signal  from the detector  and the  LCD  will  display  the Detector   registration  No 

and its Zone  allocation  e.g. Activate  Detector  No 2 in Zone  3 the LCD  will

 

 
 
 

 

 

 

Note: The armed LED  flashes to show that the  delay  timer is being  activated for  those 

zones with delayed time. The zones without a delayed timer is armed.  When the  armed LED 

light, it  shows  Arming  has completed.  All the exterior  Zones Arm  immediately when part 

armed, the delay timer will not work under such circumstances.

 

LOG

 

M  

H  

M  

D

 

TEST

 

 
 
 
 

 

Figure 9

 

 

 

19 

8

 

Содержание ZDAS-300

Страница 1: ...Luxury Voiced LCD Alarm System USER S MANUAL Model ZDAS 300 Thank you for choosing our panel Please read the manual carefully before fixing it ...

Страница 2: ......

Страница 3: ...VIEW 1 1 1 Introduction 1 1 2 Basic Principle of Operation 1 1 3 Component Parts 2 1 4 Optional Extra Detectors available 2 2 DESCRIPTION 3 2 1 The Keypad 3 2 2 The LCD Character details and description 4 3 INSTALLATION INFORMATION 9 3 1 The Basic Flow Chart 6 3 2 Registering Key Fobs 7 3 3Registering Sensors 7 3 4 Installing Wired Detector 8 3 5 Checking Registration 8 3 6 Deleting Registered Key...

Страница 4: ...s PROG to save using this way can set C S Account in Pry 7 or other private phone No press the registered key fob ESC key to exit To set C S phone number 1 To register Key fobs 2 To register Detectors 3 To set Zone type 4 To set System configuration 5 To set C S phone NO and site code 1 OVERVIEW 1 1 Introduction 1 Blue backup LCD display everything you want to konw about the panel 2 Full complianc...

Страница 5: ...the Alarm Signals from the various Detectors It also contains the central Station communicator and By directional Audio Verification mechanism Everything you need to know about the security system is displayed on the panel keypad LCD The zones 24 Hours Armed Part armed Disarmed and the important Messages regarding system status are displayed on the LCD screen See section 2 1 and 2 2 Wireless Remot...

Страница 6: ...tect the particular frequency and then transmitting an alarm signal to the control panel 1 2 3 4 5 6 7 1 1 watchdog zone 0 not a watchdog zone 2 1 exit delay 0 no exit delay 3 1 entry delay 0 no entry delay 4 1 24 hours zone 0 not 24 hours zone 5 1 sounder when alarming 0 silent when alarming 6 1 armed zone 0 part armed zone 7 1 sensor in the zone 0 no sensor in the zone Zone 1 selected 2 DESCRIPT...

Страница 7: ...ng system status appear on the LCD screen LOG M D H M D 2 2 The LCD Character details and description 2 2 1 The panel LCD screen whole information shows as follows Figure 23 Detector No 2 in zone 3 is low voltage LOG DIS PART ARMED WatchDog M D H M D B When the panel is in the Armed PART Armed mode if the detector such as PIR detects itself being low voltage the panel will sound a beep every secon...

Страница 8: ... is transferred to the C S the operator then has access to the customer details address name phone numbers 2 2 2 When the panel is set in the away armed mode the LCD screen will show the following ARMED key holders etc He also has audio access to the premises He can Listen in or Speak to the occupants this will allow the C S operator to request a pre arranged password to confirm the identity of th...

Страница 9: ... fob will still be sounder alarm if it is set with sounder alarm 4 9 Access the Control Panel from a remote telephone mobile or land line The Remote Control enables the use of the land line phone or mobile phone to remotely control panel Call the phone number of the line connected to the alarm panel the panel will answer the call after 1 to 8 rings programmable When the panel answers the call ente...

Страница 10: ...ows particular detectors in each Zone to be local alarm only or local alarm and transmit alarm information to the C S each detector can be configured differently e g local Alarm only or local Alarm and C S function door bell function or in the case of Key Fob Request Assistance with without sounder How to set the function press Sensor key and appears on the LCD Press registered Key Fob or entering...

Страница 11: ...n the keypad a series of appear on the LCD Enter the PIN code or press the Disarm key on a registered key fob and the word Sensor will appear on the LCD Trigger the detector you wish to register the panel will receive the detectors code and the word CODE will appear on the LCD Pressing a numeric key 1 to 8 on the keypad will select the zone you wish to allocate the detector e g Pressing No 3 on th...

Страница 12: ...e No 2 detector in Zone 3 If no further actions take place the panel will automatically return to normal state after approximately 30 seconds Otherwise at the end press Dis Arm key on a registered Key Fob to return the panel to normal state 3 8 The Zone Setting and Allocation The alarm system has 8 zones which can be configured depending on your requirements The Factory Default Zone configuration ...

Страница 13: ...d PIN code and the word Sensor will appear on the LCD Pressing the key on the Keypad the LCD will show the words Zone type pressing No1 to 8 numeric key to select corresponding zone then pressing the 0 or 1 numeric Keypad to configure all the fields in this zone At the end press the PROG key to complete and save operation By way of example below is configured as follows Zone 7 selected is a Watchd...

Страница 14: ...04 20 seconds 02 Entry delay time delay alarm The time is double digit XX The actual time is the product of XX times 5 The initialization value is 06 30 seconds 03 Sounder run time The time is double digit XX The actual time is the product XX times 20 The initialization value is 06 120 seconds 04 Watchdog time The unit time is hours The factory default value is 12hours 05 Watchdog start and stop t...

Страница 15: ...is required within 2 5 seconds after transmitting data to the C S the Panel Will receive the SPEAK request from C S If it is not required the panel hangs up automatically ALM phone line cut_off alarm Figure15 The LCD display when the phone line is cut 13 Engineer Option Listen to dial out DTMF 0 NO 1 YES This option will Automatically extinguish when the panel is closed or on the hour Default 0 14...

Страница 16: ...e account code using the numeric keypad on the panel this is normally a 4 Digit Code called site code Press Prog key to store the programmed number If no further actions take place the panel will automatically return to normal state after approximately 30 seconds Otherwise at the end press the Dis Arm key on a registered Key Fob to return the panel to normal state 3 12 Deleting Zones How To Delete...

Отзывы: