PT-9230 Mobile Computer SDK Programming Manual
168
17
Industrial 2 of 5
1
Read
0:Disable *
1:Enable
4
Max. code length
4 ~ 48
48 *
5
Min. code length
4 ~ 48
4 *
18
Interleaved 2 of 5
1
Read
0: Disable
1: Enable *
2
Check Digit
0: Disable *
1: Validate Only
2: Validate and Transmit
4
Max. code length
4 ~ 80
80 *
5
Min. code length
4 ~ 80
4 *
20
MSI Plessey
1
Read
0: Disable *
1: Enable
3
Transmit Check Digit
0: Disable *
1: Enable
4
Max. code length
4 ~ 48
48 *
5
Min. code length
4 ~ 48
4 *
21
UK Plessey
1
Read
0: Disable *
1: Enable
3
Transmit Check Digit
0: Disable *
1: Enable
4
Max. code length
4 ~ 48
48 *
5
Min. code length
4 ~ 48
4 *
22
Telepen
1
Read
0: Disable *
1: Enable
4
Max. code length
1 ~ 60
60 *
5
Min. code length
1 ~ 60
1 *
10
0: Disable *