background image

45

 

 

43h = “C” 

FF termination string for third code To program the previous 

example using specific lengths, you would have to count any 

programmed prefixes, suffixes, or formatted characters as part of 

the length. 

SEQBLK62001241FF6A001342FF69001243FF 

The breakdown of the command line is shown below: 

SEQBLK sequence editor start command 

62 code identifier for 

Code 39 

0012 A - Code 39 sample length (11) plus CR suffix (1) = 12 

41 start character match for Code 39, 41h = “A” 

FF termination string for first code 

6A code identifier for 

Code 128 

0013 B - Code 128 sample length (12) plus CR suffix (1) = 13 

42 start character match for Code 128, 42h = “B” 

FF termination string for second code 

69 code identifier for 

Code 93 

0012 C - Code 93 sample length (11) plus CR suffix (1) = 12 

43 start character match for Code 93, 43h = “C” 

FF termination string for third code 

Содержание ArgoxScan 9500

Страница 1: ...o de Barras Manual Argox AS 9500g Imager 2D é pequeno leve portátil e fácil de usar Além de fazer a leitura de todos os tipos de código de barra ele também lê códigos bidimensionais Maxi Code Data Matrix Aztec Qr Code e vários outros www bztech com br ...

Страница 2: ...0 ...

Страница 3: ...1 ...

Страница 4: ...interface in which case the user will be required to correct the interface at his her own expenses Note All brands and trademarks shall belong to their respective owner Note Specification is subject to changes without notice FCC This device complies with Part 15 of the FCC Rules 1 This device may not cause harmful interface and 2 This device must accept any interface received including interface t...

Страница 5: ...rcodes Label Recommended steps are as follows 1 Set right host interface for your scanner 2 Set interface to optimize protocol of scanner with your host in interface section 3 Set system control of scanner such as specific adjustments double confirm power saving indicator and scanning mode which you prefer usage in system control section 4 Set code options of scanner for your usage in code option ...

Страница 6: ... 15 Interface Selection 16 RS 232 18 USB HID 22 USB Virtual COM 22 Pin Assignments 23 System Control 25 Scan 25 Indication 30 Thermal and Centering 38 Decode Search Mode 41 Output Sequence 42 Print Contrast 48 Video Reverse 48 Working Orientation 49 Code Option 50 Codabar 51 Code 39 53 Code 32 56 Interleaved 2 of 5 57 ...

Страница 7: ... 64 Telepen 66 UPC A 67 UPC E0 70 EAN JAN 13 73 EAN JAN 8 75 MSI 77 Plessey Code 78 GS1 DataBar Omnidirectional 79 GS1 DataBar Limited 79 GS1 DataBar Expanded 80 PosiCode 81 Codablock F 82 Code 16K 83 Code 49 84 PDF417 85 MicroPDF417 86 EAN UCC Composite Codes 87 Postal Codes 89 QR Code 93 Data Matrix 94 ...

Страница 8: ... Format 98 Prefix Suffix 98 Data Formatting 104 Data Format Editor Commands 107 Imaging Commands 111 OCR Programming 120 OCR Templates 124 Utilities 138 Test Chart 140 Interface ID 145 Product Code ID 146 ASCII Code Table 148 OCR Programming Chart 150 Program Chart 151 ...

Страница 9: ...7 ...

Страница 10: ...5 Once the scanner has been fully connected turn the terminal computer power back on USB HID 1 Connect the USB cable between scanner and PC 2 Windows will automatically detect the USB device USB Virtual COM 1 Install driver USB Virtual COM Driver from CD ROM The driver will use the next available COM port number 2 Connect the USB cable between scanner and PC 3 Windows will automatically detect the...

Страница 11: ...rification Enable Checksum Transmission Enable Code ID UPC A V V V c UPC E0 V V V E UPC E1 E EAN 13 V V V d EAN 8 V V V D Code 32 Code 39 V b TCIF Linked Code 39 T Code 49 I Interleaved 2 of 5 V e Industrial 2 of 5 e Straight 2 of 5 IATA f Straight 2 of 5 Industrial f Matrix 2 of 5 m Codabar V a Code 128 V j Code 93 V i Code 11 V two digits h Telepen t MSI g Plessey n ...

Страница 12: ...B V W Codablock F q Code 16K o Code 49 V I PDF 417 V r MicroPDF 417 V R EAN UCC Composite y Postnet P Planet Code L British Post B Canadia Post C Kix Post Netherlands K Australian Post A Japanese Post J China Post Q Korea Post QR Code V O Data Matrix V w MaxiCode V x Aztec Code V z Aztec Runes z ...

Страница 13: ...3 102mm 67 176mm Depth of Scan Field PCS 90 10 mils 2D QR Code 62 137 mm 34 101mm 85 168mm 1D 5mil 4mil 6 6mil Resolution 2D 8 3mil 6 7mil 15mil Print Contrast 25 or more Focal Point from lens plate 114 mm 114mm 114mm Scanning Angle Pitch 40 Skew 40 Rotational Sensitivity 360 Decode Capability Auto discriminates all standard barcodes Other symbologies can be ordered optionally Beeper Operation Vol...

Страница 14: ...Agency listing EMI FCC CE BSMI Safety UL BSMI CB Environmental Operating Temperature 0 to 50 32 to 122 Storage Temperature 20 to 60 4 to 140 Humidity Up to 95 relative humidity non condensing 50 Light Level Dark to 100 000 Lux Shock 24 drops from 1 8 m to concrete Resistance IP 42 Contaminants Seals to resist airborne particulate contaminants Ventilation None required Width handle 32 mm Width head...

Страница 15: ...characteristics Code type selection check digit selection Decoding option Decoding option Transmitted character delay Header selection trailer selection message suffix good read beep tone and volume scanner trigger selection Keyboard emulation type intermessage delay keyboard type and keyboard language Serial interface type ACK NAK Xon Xoff RTS CTS good read LED control start stop bits ...

Страница 16: ...e and larger when it is farther from the code Symbologies with smaller bars or elements mil size should be read closer to the unit Symbologies with larger bars or elements mil size should be read farther from the unit To read single or multiple symbols Linear bar code 2D Matrix symbol on a page or on an object hold the engine at an appropriate distance from the target send a trigger command and ce...

Страница 17: ...u will see a table of alphanumeric barcodes which are used to program the various options presented To program each option you must 1 Scan the Program barcodes 2 Enter the option mode by scanning the option barcodes 3 The necessary alphanumeric inputs are listed Scan these alphanumeric entries from the Program Chart To confirm above steps you must scan the Save barcode ...

Страница 18: ...figure the proper interface by following interface selection Interface selection You can change factory interface default USB Virtual COM for other type interface By plugging different cables setting right interface then scan the interface barcode power cycle the scanner will be changed to another interface However you must make sure which cable you need RS 232 Interface USB HID PC USB HID MAC USB...

Страница 19: ...17 ...

Страница 20: ...18 RS 232 Default Setting Baud Rate 115200 bps Data Format 8 data bits no parity bit 1 stop bit Baud Rate 300 600 1200 2400 4800 9600 19200 38400 57600 115200 ...

Страница 21: ... full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity provides a means of checking character bit patterns for validity Default None Data Format 7 Data 1 Stop Parity Even 7 Data 1 Stop Parity None 7 Data 1 Stop Parity Odd 7 Data 2 Stop Parity Even 7 Data 2 Stop Parity None 7 Data 2 Stop Parity Odd 8 Data 1 Stop Parity Even 8 Data 1 Stop P...

Страница 22: ...e ACK NAK protocol is used the scanner waits for an ACK acknowledge or not acknowledge from the host computer after data transmission and will resend in response to a NAK Response Delay The unit stays awake to receive data until the RS 232 Receiver Time Out expires A trigger command resets the time out When an RS 232 receiver is sleeping a character may be sent to wake up the receiver and reset th...

Страница 23: ...21 Handshaking RTS CTS On XON XOFF On ACK NAK On Response Delay RTS CTS Off XON OFF Off ACK NAK Off ...

Страница 24: ...irtual COM Scan the following code to program the AS 9500 to emulate a regular RS 232 based COM port If you are using a PC you will need to download a driver from CD ROM The driver will use the next available COM port number USB Virtual COM CTS RTS Emulation ACK NAK Mode CTS RTS On ACK NAK On CTS RTS Off ACK NAK Off ...

Страница 25: ...23 Pin Assignments 10 pin RJ 45 Connector to Scanner Side Pin RS 232 USB 1 NC NC 2 VCC VCC 3 TXD TXD 4 NC NC 5 NC NC 6 CTS D 7 RXD D 8 RTS RTS 9 GND GND 10 GND GND 1 2 4 3 5 6 7 8 9 10 ...

Страница 26: ...24 Pin Assignments Connector to Host Side Pin RS 232 USB 1 NC 5V 2 TXD D 3 RXD D 4 NC GND 5 GND 6 NC 7 CTS 8 RTS 9 VCC 4 2 3 1 8 6 9 7 5 4 1 ...

Страница 27: ...hen in serial mode the imager scans until a bar code has been read or until the deactivate command is sent In serial mode the imager can also be set to turn itself off after a specified time has elapsed see Read Time Out which follows Manual Trigger Low Power For RS 232 only The imager powers down until the trigger is pulled When the trigger is pulled the imager powers up and operates until there ...

Страница 28: ...ense Mode may not work properly Snap and Ship Snap and Ship mode allows you to bypass the decoder and ship an image directly to the host In this mode an image is taken and shipped upon each trigger pull instead of being sent to the decoder Snap and Ship is useful when you are using your own decoder Note Snap and Ship mode only works if the imager is connected via an RS 232 serial port or via a USB...

Страница 29: ...27 Scanning Output VGA Off VGA On Scanning Mode Manual Serial Trigger Auto sense Mode Manual Trigger Low Power Snap and Ship ...

Страница 30: ...er mode Whenever the trigger is enabled the low power time out timer is reset Auto sense LED Behavior after Decode When an imager is in Auto sense mode the LEDs remain on and continue scanning for a short time after a bar code is decoded If you wish to turn the LEDs off immediately after a bar code is decoded scan the LEDs Off bar code below Default LEDs On Auto sense LED Time Out When using Auto ...

Страница 31: ...can set the time the imager should remain in manual trigger mode by setting the Hands Free Time Out Once the time out value is reached if there have been no further trigger pulls the imager reverts to the original hands free mode Scan the Hands Free Time Out bar code then scan the time out duration from 0 300 000 milliseconds from the inside back cover and Save Default 5 000 ms Read Time out Read ...

Страница 32: ...till audible Volume The beeper volume codes modify the volume of the beep the imager emits on a good read Frequency The beeper pitch codes modify the pitch of the beep the imager emits on a good read Duration The beeper duration codes modify the length of the beep the imager emits on a good read Beeper On Off Volume Low High Medium Extreme Low Frequency Low Medium High Duration Normal Beep Short B...

Страница 33: ... vibrator or beeper is ON then the LED indicator will remain On all the time Vibrator The vibrator provides a unique feature to AS 9500 that user can understand whether the data is well scanned and sent to Host PC under an adverse circumstance that the beep sound may not be heard or a circumstance requiring extreme quiet that the beep sounds are not allowed Vibrator On Off ...

Страница 34: ...fied time To prevent the imager from powering down set this time out to 0 Scan the bar code below then set the time out by scanning digits from 0 999 999 ms from the inside back cover then scanning Save Default 1 ms Reread Delay This sets the time period before the imager can read the same bar code a second time Setting a reread delay protects against accidental rereads of the same barcode Longer ...

Страница 35: ...w then set the delay from 0 30 000 milliseconds by scanning digits from the inside back cover then scanning Save Illumination Light Lights On Lights Off Imager Time Out Imager Time Out Reread Delay Short 500 ms Long 1000 ms Medium 750ms Extra Long 2000 ms User Specified Reread Delay User Specified Reread Delay ...

Страница 36: ...mode provides the lowest overall current draw and is recommended for most applications It also provides the brightest aimer in most applications The Image Engine software automatically maintains an approximate 25 aimer duty cycle even when the imager exposure time is at its maximum in dark operating environments Concurrent is provided for backwards compatibility with the 4X00 Image Engine series a...

Страница 37: ...des This mode may be useful for applications when an operator is using the illumination LEDs for aiming such as in fixed mount kiosk or auto trigger applications Select Off if you don t want to use either aimer mode Aimer Delay 200Milliseconds Off no delay 400Milliseconds Delay Duration Aimer Modes Concurrent Interlaced Off ...

Страница 38: ...read The beeps and LED flashes are in sync with one another To change the number of beeps scan the bar code below and then scan a digit 1 9 bar code and the Save bar code Good Read Delay This sets the minimum amount of time before the imager can read another bar code Default No Delay User Specified Good Read Delay If you want to set your own length for the good read delay scan the bar code below t...

Страница 39: ...37 Number of Beep Number of Pulses Good Read Delay No Delay Medium Delay 1 000 ms Short Delay 500 ms Long Delay 1 500 ms User Specified Good Read Delay User Specified Good Read Delay ...

Страница 40: ...e performance will also degrade The Power Control PWM can be used to reduce the effect of the Illumination LEDs on thermal rise however this also reduces the intensity of the illumination Reducing the intensity of the illumination reduces total power used but can also reduce the depth of field in low light environments Centering Use Centering to narrow the imager s field of view to make sure the i...

Страница 41: ...96 pixel area 640x480 default image size in the center of the imager s field of view The following diagram illustrates the default top bottom left and right pixel positions measured from the top and the left side of the imager s field of view ...

Страница 42: ...ottom Left or Right bar codes Scan Centering On then scan one of the following bar codes to change the top bottom left or right of the centering window Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual Scan Save Default Centering 40 for Top and Left 60 for Bottom and Right Centering On Top of Centering Window Left of Centering Window ...

Страница 43: ...egion of an image This mode quickly reads all symbologies in any orientation The Quick Omnidirectional mode may miss some off center symbols as well as larger Data Matrix and QR Code Advanced Linear Decoding Performs quick horizontal linear scans in a center band of the image This mode does quickly read linear and stacked bar codes Advanced Linear Decoding cannot read 2D OCR or Postal symbols Full...

Страница 44: ...n you want to delete or clear all formats before you read the Default Sequence symbol Note To make Output Sequence Editor selections you ll need to know the code I D code length and character matches your application requires Use the Alphanumeric symbols inside back cover to read these options Note You must hold the trigger while reading each bar code in the sequence To Add an Output Sequence 1 Sc...

Страница 45: ...represents the character s you want to match Use the Programming Chart to read the alphanumeric combination that represents the ASCII characters 99 is the Universal number indicating all characters 5 End Output Sequence Editor Scan F F to enter an Output Sequence for an additional symbology or Save to save your entries Other Programming Selections Discard This exits without saving any Output Seque...

Страница 46: ...he breakdown of the command line is shown below SEQBLKsequence editor start command 62 code identifier for Code 39 9999 code length that must match for Code 39 9999 all lengths 41 start character match for Code 39 41h A FF termination string for first code 6A code identifier for Code 128 9999 code length that must match for Code 128 9999 all lengths 42 start character match for Code 128 42h B FF t...

Страница 47: ...tor start command 62 code identifier for Code 39 0012 A Code 39 sample length 11 plus CR suffix 1 12 41 start character match for Code 39 41h A FF termination string for first code 6A code identifier for Code 128 0013 B Code 128 sample length 12 plus CR suffix 1 13 42 start character match for Code 128 42h B FF termination string for second code 69 code identifier for Code 93 0012 C Code 93 sample...

Страница 48: ...will attempt to get the output data to conform to an edited sequence but if it cannot the imager transmits all output data to the host device as is When the output sequence is Off the bar code data is output to the host as the imager decodes it Note This selection is unavailable when the Multiple Symbols Selection is turned on Output Sequence Editor Enter Sequence Default Sequence Require Output S...

Страница 49: ... to find and decode new symbols as long as the trigger is activated When this programming selection is turned Off the Imager will only read the symbol closest to the aiming beam No Read With No Read turned On the Imager notifies you if a code cannot be read If using a Quick View Scan Data Window an NR appears when a code cannot be read If No Read is turned Off the NR will not appear Multiple Symbo...

Страница 50: ... Print Contrast from 1 7 by scanning digits from the inside back cover then scanning Save Default 4 Print Contrast Set Print Contrast Default Video Reverse Video Reverse is used to allow the imager to read bar codes that are inverted The Off bar code below is an example of this type of bar code If additional menuing is required Video Reverse must be disabled to read the menu bar codes and then re ...

Страница 51: ... and OCR can misread when scanned sideways or upside down Use the working orientation settings if your direction sensitive codes will not usually be presented upright to the scanner Default Upright Working Orientation Upright Upside Down Rotate Clockwise 90 Rotate Counterclockwise 90 ...

Страница 52: ...u may set the same value for minimum and maximum length to force the imager to read fixed length bar code data This helps reduce the chances of a misread EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message l...

Страница 53: ...t the imager will only read Codabar bar codes printed with a check character and will transmit this character at the end of the scanned data When Check Character is set to Validate but Don t Transmit the unit will only read Codabar bar codes printed with a check character but will not transmit the check character with the scanned data Default All Codabar Settings On Off Start Stop Character Transm...

Страница 54: ...ated into one with the D characters omitted Default On Select Require to prevent the imager from decoding a single D Codabar symbol without its companion This selection has no effect on Codabar symbols without Stop Start D characters Message Length Scan the bar codes below to change the message length Minimum and Maximum lengths 2 60 Minimum Default 4 Maximum Default 60 Message Length On Require M...

Страница 55: ...Check Character is set to Validate but Don t Transmit the unit only reads Code 39 bar codes printed with a check character but will not transmit the check character with the scanned data When Check Character is set to Validate and Transmit the imager only reads Code 39 bar codes printed with a check character and will transmit this character at the end of the scanned data Default No Check Characte...

Страница 56: ...computer When this function is enabled the imager stores those Code 39 bar codes that start with a space excluding the start and stop symbols and does not immediately transmit the data The imager stores the data in the order in which the bar codes are read deleting the first space from each The imager transmits the appended data when it reads a Code 39 bar code that starts with a character other t...

Страница 57: ...n the bar code symbol will be interpreted as a single character For example V will be decoded as the ASCII character SYN and C will be decoded as the ASCII character Character pairs M and N decode as a minus sign and period respectively Character pairs P through Y decode as 0 through 9 ...

Страница 58: ...expecting If this is the case scan the bar code below select the code page with which the bar codes were created and scan the value and the Save bar code The data characters should then appear properly Full ASCII On Code 39 Code Page Full ASCII Off Code 32 Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies This symbology is also known as PARAF Note Trioptic Code m...

Страница 59: ...t with the scanned data When Check Digit is set to Validate and Transmit the imager only reads Interleaved 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Message Length Scan the bar codes below to change the message length Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Default All Interleaved 2 of 5 Settings On No Chec...

Страница 60: ...it may be because the barcode being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual The data characters should then appear properly De...

Страница 61: ...age Length Scan the bar codes below to change the message length Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Default All Straight 2 of 5 Industrial Settings On Minimum Message Length Off Maximum Message Length ...

Страница 62: ...age Length Scan the bar codes below to change the message length Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Default All Straight 2 of 5 IATA Settings On Maximum Message Length Off Minimum Message Length ...

Страница 63: ...age Length Scan the bar codes below to change the message length Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Default All Matrix 2 of 5 Settings On Minimum Message Length Off Maximum Message Length ...

Страница 64: ... Code 11 bar codes Default Two Check Digits Message Length Scan the bar codes below to change the message length Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Default All Code 11 Settings On One Check Digit Minimum Message Length Off Two Check Digits Maximum Message Length ...

Страница 65: ...63 ...

Страница 66: ...es below to turn concatenation on or off Default Off Message Length Scan the bar codes below to change the message length Minimum and Maximum lengths 0 80 Minimum Default 0 Maximum Default 80 Code Page Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code ...

Страница 67: ...65 Default All Code 128 Settings On ISBT 128 On Minimum Message Length Off ISBT 128 Off Maximum Message Length Code Page Code 128 Code Page ...

Страница 68: ... reads symbols with start stop pattern 1 and decodes them as compressed numeric with optional full ASCII start stop pattern 2 Default AIM Telepen Output Message Length Scan the bar codes below to change the message length Minimum and Maximum lengths 1 60 Minimum Default 1 Maximum Default 60 Default All Telepen Settings On AIM Telepen Output Minimum Message Length Off Original Telepen Output Maximu...

Страница 69: ... the end of the scanned data or not Default On Number System The numeric system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will not transmit it Default On Default All UPC A Settings On Off Check Digit On Off Number System On Off ...

Страница 70: ...UPC A bar codes that have addenda You must then turn on a 2 or 5 digit addenda Default Not Required Addenda Separator When this feature is on there is a space between the data from the bar code and the data from the addenda When turned off there is no space Default On UPC A EAN 13 with Extended Coupon Code Use the following codes to enable or disable UPC A and EAN 13 with Extended Coupon Code Defa...

Страница 71: ...69 Addenda 2 Digit Addenda On 5 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda Off Addenda Required Required Not Required Addenda Separator On Off UPC A EAN 13 with Extended Coupon Code On Off ...

Страница 72: ...ger will only read UPC E bar codes that have addenda Addenda Separator When this feature is on there is a space between the data from the bar code and the data from the addenda When turned off there is no space Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not Default On Number System The numeric system digit of a U P C symbol is ...

Страница 73: ...71 Default All UPC E Settings UPC E0 On UPC E0 Off UPC E0 Expand On Off Addenda Required Required Not Required Addenda Separator On Off Check Digit On Off Number System On Off ...

Страница 74: ... Digit and 5 Digit Addenda UPC E1 Most U P C bar codes lead with the 0 number system For these codes If you need to read codes that lead with the 1 number system use the UPC E1 selection Default Off Addenda 2 Digit Addenda On 5 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda Off UPC E1 UPC E1 On UPC E1 Off ...

Страница 75: ... the check digit should be transmitted at the end of the scanned data or not ISBN Translate This selection causes EAN 13 Bookland symbols to be translated into their equivalent ISBN number format Default All EAN JAN Settings On Off Check Digit On Off ISBN Translate On Off ...

Страница 76: ... will only read EAN JAN 13 bar codes that have addenda Addenda Separator When this feature is on there is a space between the data from the bar code and the data from the addenda When turned off there is no space Addenda 2 Digit Addenda On 5 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda Off Addenda Required Required No Required Addenda Separator On Off ...

Страница 77: ...end of the scanned data or not Default On Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 8 data Default Off for both 2 Digit and 5 Digit Addenda Default All EAN JAN 8 Settings On Off Check Digit On Off Addenda 2 Digit Addenda On 5 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda Off ...

Страница 78: ...l only read EAN JAN 8 bar codes that have addenda EAN JAN 8 Addenda Separator When this feature is on there is a space between the data from the bar code and the data from the addenda When turned off there is no space Addenda Required Required Not Required Addenda Separator On Off ...

Страница 79: ...s character at the end of the scanned data When Check Character is set to Validate but Don t Transmit the unit will only read MSI bar codes printed with the specified type check character but will not transmit the check character with the scanned data Message Length Scan the bar codes below to change the message length Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Default A...

Страница 80: ...age Length Scan the bar codes below to change the message length Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Default All Plessey Code Settings On Minimum Message Length Off Maximum Message Length ...

Страница 81: ...79 GS1 DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings On Off GS1 DataBar Limited Default All GS1 DataBar Limited Settings On Off ...

Страница 82: ...age Length Scan the bar codes below to change the message length Minimum and Maximum lengths 4 74 Minimum Default 4 Maximum Default 74 Default All GS1 DataBar Expanded Settings On Minimum Message Length Off Maximum Message Length ...

Страница 83: ...efault 4 Maximum Default 48 Trioptic Code Note If you are going to scan Code 32 Pharmaceutical codes Trioptic Code must be off Trioptic Code is used for labeling magnetic storage media Default All PosiCode Settings On A and B On No Limited A and B and Limited B On Limited A Off Off A and B and Limited On Limited B Off Message Length Minimum Message Length Maximum Message Length Trioptic Code On Of...

Страница 84: ...e Length Scan the bar codes below to change the message length Minimum and Maximum lengths 1 2048 Minimum Default 1 Maximum Default 2048 Default All Codablock F Settings On Minimum Message Length Off Maximum Message Length ...

Страница 85: ...ge Length Scan the bar codes below to change the message length Minimum and Maximum lengths 0 160 Minimum Default 1 Maximum Default 160 Default All Code 16K Settings On Minimum Message Length Off Maximum Message Length ...

Страница 86: ...age Length Scan the bar codes below to change the message length Minimum and Maximum lengths 1 81 Minimum Default 1 Maximum Default 81 Default All Code 49 Settings On Minimum Message Length Off Maximum Message Length ...

Страница 87: ...e Length Scan the bar codes below to change the message length Minimum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 Default All PDF417 Settings On Minimum Message Length Off Maximum Message Length ...

Страница 88: ...ge Length Scan the bar codes below to change the message length Minimum and Maximum lengths 1 366 Minimum Default 1 Maximum Default 366 Default All Micro PDF417 Settings On Minimum Message Length Off Maximum Message Length ...

Страница 89: ... 1 2435 Minimum Default 1 Maximum Default 2435 Emulation The imager can automatically format the output from any EAN UCC data carrier to emulate what would be encoded in an equivalent UCC EAN 128 or GS1 DataBar and Composite symbol EAN UCC data carriers include UPC A and UPC E EAN 13 and EAN 8 ITF 14 UCC EAN 128 and EAN UCC GS1 DataBar and Composites Data from 2D symbols such as Aztec Code Data Ma...

Страница 90: ...Code 39 linear component The MicroPDF417 component can only be decoded if TLC39 On is selected The linear component may be decoded as Code 39 even if TLC39 is off EAN UCC Composite Codes On Off UPC EAN Version UPC EAN Version On UPC EAN Version Off Message Length Minimum Message Length Maximum Message Length Emulation GS1 DataBar Emulation EAN UCC Emulation Off 128 Emulation TCIF Link Code 39 TLC3...

Страница 91: ...s Engine Postnet Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data On Transmit Check Digit Off Don t Transmit Check Digit Planet Code Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data On Transmit Check Digit Off Don t Transmit Check Digit ...

Страница 92: ...90 Postal Codes British Post On Off Canadian Post On Off Kix Netherlands Post Note Kix code can misread when scanned sideways or upside down On Off Australian Post On Off Japanese Post On Off ...

Страница 93: ...age Length Scan the bar codes below to change the message length Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Default All China Post Settings On Minimum Message Length Off Maximum Message Length ...

Страница 94: ...st Message Length Scan the bar codes below to change the message length Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 Default All Korea Post Settings On Minimum Message Length Off Maximum Message Length ...

Страница 95: ...Code and Micro QR Code Message Length Scan the bar codes below to change the message length Minimum and Maximum lengths 1 3500 Minimum Default 1 Maximum Default 3500 Default All QR Code Settings On Minimum Message Length Off Maximum Message Length ...

Страница 96: ...e Length Scan the bar codes below to change the message length Minimum and Maximum lengths 1 1500 Minimum Default 1 Maximum Default 1500 Default All Data Matrix Settings On Minimum Message Length Off Maximum Message Length ...

Страница 97: ...ge Length Scan the bar codes below to change the message length Minimum and Maximum lengths 1 150 Minimum Default 1 Maximum Default 150 Default All MaxiCode Settings On Minimum Message Length Off Maximum Message Length ...

Страница 98: ...imum Default 1 Maximum Default 3750 Default All Aztec Code Settings On Minimum Message Length Off Maximum Message Length Aztec Runes Select Enable Runes if you are scanning Aztec runes which are the smallest type of Aztec Code symbol with the ability to encode a very short license plate message Enable Runes Disable Runes ...

Страница 99: ...Code Message Length Scan the bar codes below to change the message length Minimum and Maximum lengths 1 7833 Minimum Default 1 Maximum Default 7833 Default All Han Xin Settings On Minimum Message Length Off Maximum Message Length ...

Страница 100: ... shows the breakdown of a message string Prefix Suffix characters setting Characters defined as prefix or suffix characters will be transmitted immediately with the scanned data for all symbologies Up to 11 ASCII characters can be defined for both Prefix and Suffix Tips A prefix or suffix may be added or cleared from one symbology or all symbologies You can add any prefix or suffix f plus Code I D...

Страница 101: ...prefix or suffix character Step 7 To add the Code I D scan 5 C 8 0 To add AIM I D scan 5 C 8 1 To add a backslash scan 5 C 5 C Note To add a backslash as in Step 7 you must scan 5C twice once to create the leading backslash and then to create the backslash itself Step 8 Scan Save to exit and save or scan Discard to exit without saving Repeat Steps 1 6 to add a prefix or suffix for another symbolog...

Страница 102: ...ine the 2 digit Hex value for the symbology from which you want to clear the prefix or suffix Step 3 Scan the 2 digit hex value or scan 9 9 for all symbologies Your change is automatically saved To Add a Carriage Return Suffix to all Symbologies Scan the following bar code if you wish to add a carriage return suffix to all symbologies at once This action first clears all current suffixes then prog...

Страница 103: ...if data comes through too quickly Intercharacter interfunction and intermessage delays slow the transmission of data increasing data integrity Each delay is composed of a 5 millisecond step You can program up to 99 steps of 5 ms each for a range of 0 495 ms Intercharacter Delay An intercharacter delay of up to 495 milliseconds may be placed between the transmission of each character of scanned dat...

Страница 104: ...econds may be placed after the transmission of a particular character of scanned data Scan the Delay Length bar code below then scan the number of milliseconds and the SAVE bar code Next scan the Character to Trigger Delay bar code then the 2 digit hex value for the ASCII character that will trigger the delay User Specified Intercharacter Delay Delay Length Character Trigger Delay To remove this d...

Страница 105: ... To remove this delay scan the Interfunction Delay bar code then set the number of steps to 0 Scan the SAVE bar code Intermessage Delay An intermessage delay of up to 495 milliseconds may be placed between each scan transmission Scan the Intermessage Delay bar code below then scan the number of milliseconds and the SAVE bar code Intermessage Delay To remove this delay scan the Intermessage Delay b...

Страница 106: ...iple formats may be programmed into the imager They are stacked in the order in which they are entered However the following list presents the order in which formats are applied 1 Specific Term ID Actual Code ID Actual Length 2 Specific Term ID Actual Code ID Universal Length 3 Specific Term ID Universal Code ID Actual Length 4 Specific Term ID Universal Code ID Universal Length 5 Universal Term I...

Страница 107: ... three numeric bar codes on the inside back cover to program the imager for your Interface ID you must enter 3 digits For example scan 0 0 0 for RS 232 Note The wildcard for all terminal types is 099 Step 4 Code I D Find the symbology to which you want to apply the data format Locate the Hex value for that symbology and scan the 2 digit hex value Step 5 Length Specify what length up to 9999 charac...

Страница 108: ... alternate format you are clearing Scan the Interface Type and Code I D and the bar code data length for the specific data format that you want to delete All other formats remain unaffected Save This exits saving any Data Format changes Discard This exits without saving any Data Format changes Enter Data Format Clear One Data Format Save Default Data Format Clear All Data Formats Discard ...

Страница 109: ...er nn times Insert leaving cursor in current cursor position Syntax F4xxnn xx stands for the hex value for an ASCII code and nn is the numeric value 00 99 for the number of times it should be sent E9 Send all but the last nn characters starting from the current cursor position Syntax E9nn nn is the numeric value 00 99 for the number of characters that will not be sent at the end of the message Mov...

Страница 110: ...5 different characters starting at the current cursor position as the cursor is advanced by other commands When the FC command is encountered the suppress function is terminated The cursor is not moved by the FB command Syntax FBnnxxyy zz where nn is a count of the number of suppressed characters in the list and xxyy zz is the list of characters to be suppressed xx stands for the hex value for an ...

Страница 111: ... character at the current cursor position If character is numeric format is aborted Syntax ED Data Formatter When Data Formatter is turned off the bar code data is output to the host as read including prefixes and suffixes Choose one of the following options Default Data Formatter On but Not Required Data Formatter On but Not Required Data Formatter Off When Data Formatter is required all input da...

Страница 112: ... input whether you are programming the primary format or an alternate format numbered 1 2 or 3 An alternate format is initiated by scanning one of the 3 alternate format bar codes below The imager will scan the next bar code formatting the data with the selected alternate format then revert immediately to the primary format Alternate Data Format 1 Alternate Data Format 2 Alternate Data Format 3 ...

Страница 113: ...iers that can be used to change the look of the image in memory Modifiers always begin with numbers and end with a letter case insensitive Any number of modifiers may be appended to the IMGSNP command For example you can use the following command to snap an image increase the gain and have the beeper sound once the snap is complete IMGSNP2G1B IMGSNP Modifiers P Imaging Style Sets the Image Snap st...

Страница 114: ... white value setting see W Target White Value Delta is only available when using Photo Style Default 25 nD Range 0 255 L LED State Determines if the LEDs should be on or off and when Ambient illumination 0L is preferred for taking pictures of color documents such as ID cards especially when the imager is in a stand LED illumination 1L is preferred when the imager is handheld LED State is not avail...

Страница 115: ...o alter grayscale values Target White Value should be used Default 50 n Range 1 99 Image Ship IMGSHP An image is taken whenever the Image Snap IMGSNP command is processed The last image is always stored in memory You may ship the image by using the IMGSHP command The image ship command has many different modifiers that can be used to change the look of the image output by the scanner Modifiers aff...

Страница 116: ...n n 1 24 F File Format Indicates the desired format for the image 0F KIM format 1F TIFF binary 2F TIFF binary group 4 compressed 3F TIFF grayscale 4F Uncompressed binary upper left to lower right 1 pixel bit 0 padded end of line 5F Uncompressed grayscale upper left to lower right bitmap format 6F JPEG image default 8F BMP format lower right to upper left uncompressed H Histogram Stretch Increases ...

Страница 117: ... gamma correction yields an overall brighter image The lower the setting the darker the image A setting of 100 results in no adjustment to the image The optimal setting is 50K This selection should only be used for text images 0K Gamma correction off default 60K Apply gamma correction for brightening typical document image nK Apply gamma correction factor n n 1 255 L R T B M Image Cropping Ship a ...

Страница 118: ...ata that is sent 0P None raw data 2P None default for USB 3P Hmodem compressed default for RS 232 4P Hmodem S Pixel Ship Can be used to decimate the image by shipping only certain regularly spaced pixels For example 4S would transmit every fourth pixel from every fourth line The smaller number of pixels shipped the smaller the image However after a certain point the image becomes unusable 1S ship ...

Страница 119: ... Don t ship histogram default 1W Ship histogram Intelligent Signature Capture IMGBOX IMGBOX commands can only be used with PDF417 Code 39 Code 128 Aztec Codabar and Interleaved 2 of 5 symbologies Intelligent signature capture ships only part of an image to the host application This method reduces transfer time and file size while simplifying signature capture Below is an example of an intelligent ...

Страница 120: ...nner s field of view The intelligent signature capture command string for this application is IMGBOX40S0X70Y190W100H1R0F IMGBOX Modifiers D Pixel Depth Indicates the number of bits per pixel in the transmitted image 8D 8 bits per pixel grayscale image 1D 1 bit per pixel black and white image negative positive F File Format Indicates the type of file format in which to save the image 0F KIM format ...

Страница 121: ...lso the larger the file size S Bar Code Aspect Ratio The ratio of the bar code height to the narrow element width In the example the narrow element width is 010 inches and the bar code height is 0 400 inches resulting in a value of S 0 4 0 01 40 W Width of Signature Capture Area In the example the width of the area to be captured is 1 90 inches resulting in a value of W 1 9 0 01 190 The value for ...

Страница 122: ...U S Currency Serial Number Money MICR E 13B and SEMI fonts You can either select an OCR default or create your own custom template for the type of OCR format you intend to read See OCR on page 9 1 for programming codes that will enable your imager to read OCR A OCR B U S Currency MICR E 13B or SEMI fonts See OCR Templates on page 9 3 if you want to create a custom template or character string that...

Страница 123: ...rking Orientation if your OCR symbols will not usually be presented upright to the scanner Only one OCR symbology can be read at a time OCR A On allows you to scan characters in the OCR A font The default setting allows you to scan any eight digit combination If you have created an OCR template character combinations that fit the template can be scanned OCR B On allows you to scan characters in th...

Страница 124: ...er combinations that fit the template can be scanned U S Currency On MICR E 13B Font MICR E 13B On allows you to scan MICR characters on a bank check The default setting allows you to scan any eight digit combination If you have created an OCR template character combinations that fit the template can be scanned MICR E 13B On Note TOAD characters Transit On Us Amount and Dash are output in the foll...

Страница 125: ... semiconductor industry SEMI Font On All OCR Off turns off all OCR capability in the imager so the imager will be able to scan linear stacked matrix and composite bar codes but not OCR fonts However any OCR templates you have created will be retained in memory All OCR Off ...

Страница 126: ...ther several formats and you can create a template for a user defined variable These choices are described in detail below Creating an OCR Template A single template allows you to program the imager to read any combination of characters in the order you specify Refer to examples that follow the Template Characters table below Template Characters Note OCR templates default to eight digits no check ...

Страница 127: ...e template would be dddddddd To create this template you would enable the OCR A font Scan the Enter OCR Template symbol then scan the d from the OCR Programming Chart in the back of this manual eight times Scan Save OCR Template This would let you read any string of eight digits for example Character Match Sequences On the ASCII Chart find the Hex value that represents the character s you want to ...

Страница 128: ...ic characters ABC space three digits The template would be To create this template you would enable the OCR A font Scan the Enter OCR Template symbol Scan the d from the OCR Programming Chart in the back of this manual three times then scan 2041424320 from the inside back cover the hex characters for space A B C space Scan the d three more times then scan Save OCR Template This would let you read ...

Страница 129: ... four digits two uppercase letters and two digits The template would be ddddddddtddddlldd To create this template you would enable the OCR A font Scan the Enter OCR Template symbol Scan the d from the OCR Programming Chart in the back of this manual eight times then scan the t to create the or statement Then you would scan the characters for the second template Scan d four times scan l two times t...

Страница 130: ...can then be used in an OCR template to define the variable you specified Example You need a variable to represent the letters A B or C The template for this variable would be 414243 To create this template you would enable the OCR A font Scan the Enter User Defined Variable g symbol Scan 414243 the hex characters for A B and C Scan Save OCR Template This will let you read either A or B or C in any...

Страница 131: ...is template is the default OCR template If you wanted to read the second line of data you would use the following template OCRTMP llllllll To read both lines of OCR at one time use the variable r to indicate the start of a new row All the other templating variables for the individual rows work the same as previously described For instance in the above example you would use the following template t...

Страница 132: ... data without the check character data You must specify the location of the check character in the template with a c Example You need to read any combination of seven digits with a modulo 10 check character in the eighth position The template would be dddddddc To create this template you would enable the OCR A font Scan the Modulo 10 Check Character symbol Then scan the Enter OCR Template symbol a...

Страница 133: ...ol to program the OCR template for a simple modulo 10 checksum of the digits 0 through 9 OCR Modulo 36 Check Character Scan this symbol to program the OCR template for a simple modulo 36 checksum of the digits 0 through 9 and the letters A through Z ...

Страница 134: ...s in order 0123456789X Also enter the OCR template dddddddc Enable the OCR A font then scan the following string The imager performs the following check character computation 6 5 1 2 3 5 1 X modulo 11 0 Since the result is zero the message is considered to be valid so the reader outputs the message 6512351 Programming a User Defined Check Character 1 Scan the Enter OCR Check Character bar code bel...

Страница 135: ...f two neighboring characters are transposed a common error when an operator keys in data Weighted Modulo 10 Check Character Starting with the check character and working backward through the message the imager applies a multiplier of 1 then 3 then 1 then 3 and so on This is the checking scheme used in many EAN UCC symbologies including U P C and Interleaved 2 of 5 when a check digit is invoked To ...

Страница 136: ... applies a multiplier of 1 then 2 then 1 then 2 and so on When the result of the multiplication is greater than 9 add both digits to the running sum This is often referred to as the LUHN formula One common application of the LUHN formula is validate credit card numbers This is the modulo 10 checking scheme used in MSI Code and in Code 32 Pharmaceutical PARAF To apply this weighting scheme set the ...

Страница 137: ...trings on books in Japan After you have followed the steps below you will be able to scan the following ISBN number or the additional data below it depending on the line of text at which the imager is aimed 1 Scan the OCR B On bar code 2 Program the user defined variable g to comprise the ten digits plus the dash 0123456789 3 In Japan it is common for two fields to follow the ISBN number the three...

Страница 138: ...The imager automatically invokes the ISBN checksum for template rows that are 1 at least fourteen characters long 2 whose first four characters are the letters ISBN 3 whose last character is a check character and 4 when the modulo 11 check character 0123456789X is programmed OCRENA2 TMP ISBNggggggggggggctCdddd hdddEtCdddd hddddE GPG 0123456789 GPH P CHK 0123456789X These commands can be encoded in...

Страница 139: ... of OCR is not recommended Contact the factory if you have an application that requires reading four or more rows of OCR OCR Template Codes On Enter User Defined Variable h Enter User Defined Variable g Exit Selections Save OCR Template Discard OCR Template ...

Страница 140: ...rial number Resetting the Standard Product Defaults If you aren t sure what programming options are in your imager or you ve changed some options and want the standard product default settings restored scan the Standard Product Default Settings bar code below The Menu Commands lists the standard product default settings for each of the commands Test Menu When you scan the Test Menu On code then sc...

Страница 141: ...refix to All Symbologies Add Code I D Prefix to All Symbologies Temporary Show Data Format Show Serial Number Data Format Settings Serial Number Standard Product Default Settings Standard Product Default Settings Test Menu On Off ...

Страница 142: ...140 Test Chart Bar code samples marked with symbol are not enabled initially CODABAR CODE 11 CODE 128 CODE 39 CODE 93 ...

Страница 143: ...141 EAN 13 PDF 417 STANDRAD 25 CODE 16K EAN 8 INDUSTRIAL 25 87549 ...

Страница 144: ...142 UPCE INTERLEAVED 25 MATRIX 25 MSI PLESSEY UPCA UK PLESSEY PARA ...

Страница 145: ...143 GS1 DataBar Micro PDF QR Code DataMatrix Aztet ...

Страница 146: ...144 MaxiCode OCR A ...

Страница 147: ...e a USB Virtual COM device has a Interface ID of 130 You would scan the Interface ID bar code then 1 3 1 then Save If you make an error while scanning the digits before scanning Save scan the Discard code Interface Interface ID RS 232 000 USB HID PC 124 USB HID Mac 125 USB Virtual COM 130 Terminal ID Save ...

Страница 148: ...1 H3 h 0x68 Code 128 Cm j 0x6A Code 16K Km o 0x6F Code 32 X0 0x3C Code 39 Am b 0x62 Code 49 Tm I 0x6C Code 93 Gm i 0x69 Data Matrix dm w 0x77 EAN 13 E0 d 0x64 EAN 8 E4 D 0x44 EAN UCC Composite em y 0x79 EAN 13 w Extended Coupon Code E3 d 0x64 Interleaved 2 of 5 Lm e 0x65 Japanese Post X0 J 0x4A KIX Post X0 K 0x4B Korea Post X0 0x3F Matrix 2 of 5 X0 m 0x6D MaxiCode Um x 0x78 MicriPDF417 Lm R 0x52 M...

Страница 149: ...x72 Planet Code X0 L 0x4C Plessey Code P0 n 0x6E PosiCode pm W 0x57 Postnet X0 P 0x50 QR Code Qm s 0x73 GS1 DataBar Family em y 0x79 Straight of 2 of IATA Rm f 0x66 TCIF Linked Code 39 L2 T 0x54 Telepen Bm t 0x74 Trioptic Code X0 0x3D UCC EAN 128 C1 I 0x49 UPC A E0 c 0x63 UPC A w Extended Coupon Code E3 c 0x63 UPC E E0 E 0x45 VeriCode X0 v 0x76 ...

Страница 150: ...148 ASCII Code Table ...

Страница 151: ...149 ...

Страница 152: ...150 OCR Programming Chart Save OCR Template Discard OCR Template ...

Страница 153: ...151 Program Chart ...

Страница 154: ...152 ...

Отзывы: