Connecting the Printer
The interfaces of AME-3230 include RS-232 and USB (2.0).
The interfaces of AME-3230B include RS-232, USB (2.0) and
Bluetooth 2.0.
The interfaces of AME-3230W include RS-232, USB(2.0) and
802.11b/g.
USB and RS-232 communication cables are optional accessories.
USB & RS-232 Communications:
No additional setups are required for cable communications.
USB
:
Once USB cable is connected, printer will detect
automatically and link to host, without emitting beeps.
RS-232
:
When printer is off and RS-232 cable is connected, printer
will emit 3 beeps and automatically switch to RS-232
mode. Next time printer is turned on with RS-232 cable
connected, printer will emit 1 beep (Bluetooth mode), and
then 3 beeps to indicate RS-232 mode.
When RS-232 cable is disconnected, printer will emit 1
beep and switch back to Bluetooth mode.
Note:
Turn off the printer before connecting or disconnecting USB
or RS-232 interface cables
Note:
The Communication Indicator will blink blue during data
transmission via all interfaces
– Bluetooth, RS-232,
802.11b/g and USB.