2-2. Major Component Specifications
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Part No. POW–KM98EH(A) - POW-K8EH(B)
Controls
Microprocessor
Control circuit fuse
250 V – 3.15 A
Remote Control Unit RCS–8MHPN3E
Type
Cross–flow
Number ... Dia. and length mm 1 ... ø95 / L617
Fan motor model ... Number KFV4Q–11H5P -S... 1
No. of poles ... rpm (230 V, High) 4 ... 1190
Nominal output
W
10
Coil resistance (Ambient temp. 20°C)
Ω
WHT – BRN : 561.8
WHT – VLT : 197.4
VLT – ORG : 63.4
ORG – YEL : 155.7
YEL – PNK : 115.9
Safety
Type
Internal thermal fuse
devices
Operating temp.
Open
°C
145 ± 2
Close
—
Run capacitor
µF 0.8
VAC
440
Type
Stepping motor
Model
MP24GA1
Rating
DC 12 V
Coil resistance (Ambient temp. 25°C)
Ω
WHT – BLU (respectively 4 wires) : 380 ± 7%
Coil
Aluminum plate fin / Copper tube
Rows
2
Fin pitch
mm
1.4
Face area m
2
0.130
Heat
Exch. Coil
Flap Motor
Fan & Fan Motor
Controller
PCB
6
Indoor Unit AWR509DHL
Содержание Euro-Line AER518DH
Страница 24: ...8 2 Electric Wiring Diagram 19 Indoor Unit AWR509DHL...
Страница 25: ...Indoor Unit AFR509DHL 20...
Страница 26: ...Outdoor Unit AER518DH 21...
Страница 55: ...13 ARRANGEMENT OF ELECTRICAL COMPONENT Outdoor Unit AER518DH 50...