OUTDOOR UNIT:
AE64AC3/ACL3
AE64AH3
COOLING
performance at
Rating conditions
Running Amps.
A
Power input
Kw
Rating Conditions:
Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
HEATING
performance at
Rating conditions
Running Amps.
A
Power input
Kw
Rating Conditions:
Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Full load conditions
Running Amps.
A
Power input
Kw
NOTE: Data related to matching with
AW64AL
For other indoor unit models there could be the same differences.
6,14
2,90
Complete Unit
Complete Unit
4,10
2,26
4,30
2,4
380V 3-Phase 50 Hz
380V 3-Phase 50 Hz
18
Содержание AE64AC
Страница 11: ...3 DIMENSIONAL DATA Outdoor Unit AE64AC ACL AE64AH AE64AC3 ACL3 11...
Страница 12: ...4 REFRIGERANT FLOW DIAGRAM Indoor Unit Outdoor Unit AE64AC ACL AE64AC3 ACL3 12...
Страница 13: ...Indoor Unit Outdoor Unit AE64AH AE64AH3 13...
Страница 19: ...6 2 Electric Wiring Diagram OUTDOOR UNIT AE64AC ACL AE64AH OUTDOOR UNIT AE64AC3 ACL3 AE64AH3 19...
Страница 20: ...6 3 System Wiring Diagram AE64AC ACL AE64AH AE64AC3 ACL3 AE64AH3 20...
Страница 21: ...Via Varese 90 21013 Gallarate Va Italy Tel 39 0331 755111 Fax 39 0331 776240 www argoclima it...