Step seven: connect the indoor unit electrical cable
1. Open the panel. Remove the screw that
secures the small panel covering the terminal
board.
2. Insert the indoor and outdoor unit connecting
cable into the rear hole corresponding to the
terminal block. Then pull it out of the front.
pannello
panel
vite
screw
coperchio
cablaggio
wiring
cover
foro
di
passaggio
cable
cavo
through
‐
hole
cavo
di
alimentazione
power
cable
6. Remove the cable clip. Connect the power cable to the terminal block according to colour. Tighten
the screw and secure the power cable with the clip.
blu
blue
nero
black
marrone
brown
giallo
‐
verde
yellow
‐
green
collegamento
unità
esterna
Outdoor
unit
connection
4. Reposition the terminal block cover and tighten the screws.
5. Close the panel.
N.B.:
• All wiring must be connected as shown on the unit's wiring diagram.
All indoor and outdoor unit cables must be connected by a qualified technician.
•
If the power cable is not long enough, contact the supplier for a new one. Do not attempt to extend
it yourself.
• For air conditioners equipped with a plug, the plug must be easily accessible upon completion of
installation.
• For air conditioners without a plug, install a circuit breaker on the line.
The circuit breaker must
be single-pole and the contact gap must be greater than 3mm.
Step eight: bind the pipes
1. Bind together the connecting pipe, the power
cable and the drain pipe with binding tape.
tubo
di
collegamento
connecting
pipe
tubo
di
scarico
drain
pipe
coperchio cablaggio
vite
pannello
cavo di
alimentazione
foro di
passaggio
cavo
tubo di scarico
tubo di collegamento
cavo di alimentazione interno
fascetta