Argo SLIMMY Скачать руководство пользователя страница 7

 

21

V 12/15 

HOW TO USE THE APPLIANCE 

 

 
This appliance can be used for cooling, dehumidifying and ventilating.  
When switching between modes, the fan continues to rotate but the compressor stops: the compressor will start after 3 
minutes. This delay protects the compressor from potential damage. 
 

 
THE DISCHARGE TUBE MUST ALWAYS BE CONNECTED to the appliance: the only exception is when the 
appliance is used solely for dehumidification, in which case it is advisable to let the appliance discharge directly 
into the environment for maximum efficiency (consult the "Dehumidification Mode" paragraph). 

Regularly clean the air filters beneath the easily removable rear grille to keep the air conditioner working efficiently. 

OPERATING MODES 

 
1. COOLING MODE (COOL)

 

  The first time it is turned on, the air conditioner operates in cooling mode with the default temperature set to 25 ºC. 

  The "Cool" LED on the control panel will turn on. 

  The temperature can be adjusted to between 16 °C and 30 °C. 

  In this mode, whenever the ON/OFF button is pressed, the unit switches off, the appliance saves the temperature 

setting and, when switched back on again, retains this setting. 

  In this mode, the fan speed can be adjusted and the Timer and SLEEP functions can be set. 

  For more silent operation, run the fan at low speed. 

 

2. DEHUMIDIFICATION MODE (DRY)

 

 

Press the MODE button to select Dry. 

 

The temperature is controlled by the PCB and cannot be regulated. 

 

In this mode, whenever the ON/OFF button is pressed, the unit switches off, the appliance saves the settings and, 
when switched back on again, retains them. 

 

The fan speed is set to low and cannot be adjusted. 

NOTE 

The air conditioner does not cool the room when it is used as a dehumidifier.  
When the appliance is used as a dehumidifier, the flexible hose must not be connected.  

For maximum dehumidification efficiency, leave the rear discharge attachment free to discharge directly into 
the environment. 

The dehumidification mode is recommended during autumn and winter.  

If used in summer, it is best to leave the flexible hose attached so that the hot air can be discharged towards 
the outside rather than into the room. 

During dehumidification, continuous drainage should be implemented (consult the next chapter, "CONDENSATE 
ELIMINATION"). 
 
 

 

Cooling, Ventilation

 

 
 

 

Dehumidification

 

Содержание SLIMMY

Страница 1: ...ad the instructions carefully before operating the appliance or carrying out maintenance work Observe all the safety instructions failure to observe the instructions may lead to accidents and or damag...

Страница 2: ...et Do not move the air conditioner while it is operating first turn the appliance off check for any condensate build up and empty it if necessary To turn the appliance off set the remote control to OF...

Страница 3: ...ng mode room temperature adjustment range 16 C DB 30 C DB 1 CONTROL PANEL AND FUNCTION BUTTONS WITHOUT REMOTE CONTROL 2 HORIZONTAL FINS AND AIR INTAKE 3 VERTICAL FINS AND AIR INTAKE 4 WHEELS 5 CABLE C...

Страница 4: ...nd of the tube and the end fitting for the window End fitting for window 2 Flat fitting for positioning between the air discharge outlet and the hose Hose Screws Clamp Cap Cord winder Drain hose Windo...

Страница 5: ...Connect the flat fitting to the hose extend the hose as far as necessary for reaching the outside and it connect to the back of the air conditioner Next slide the flat fitting downwards into the groo...

Страница 6: ...the flat fitting onto the hose Insert the assembled hose into the back of the air conditioner The outlet must be between 40 cm and 130 cm above the ground Avoid tight curves or bends in the flexible h...

Страница 7: ...off the appliance saves the temperature setting and when switched back on again retains this setting In this mode the fan speed can be adjusted and the Timer and SLEEP functions can be set For more s...

Страница 8: ...ON OF THE DRAINAGE HOSE 1 Remove the rubber plug at the back of the unit 1 2 Mount the clamp 2 onto the back of the unit to the right of the drainage opening 1 using a screw 3 3 Screw the drainage hos...

Страница 9: ...IVER LOCATED ON THE AIR CONDITIONER The remote control can be activated by pressing the ON OFF button on the portable unit The icon on the remote control display will flash once and a buzzer will soun...

Страница 10: ...nal transmission m T OFF off timer n T ON on timer 1 ON OFFBUTTON Press this button to switch the unit on or off When switched on the appliance will start functioning based on its last settings save f...

Страница 11: ...hat the TIMER has been set Portable unit Press TIMER Select a number of hours from 0 5 to 24 Press the TIMER button to confirm 2 Timer off automatic switch off When the appliance is running in the COO...

Страница 12: ...carrying out any cleaning or maintenance unplug the unit from the power socket 1 Cleaning the air filters The air filter must be checked at least once every two weeks of operation Operating with dirty...

Страница 13: ...livery grilles are always unobstructed the air filters are always clean a dirty filter will decrease the passage of air and thus reduce the unit performance the doors and windows are closed to avoid i...

Отзывы: