This manual is for the use of technical personnel entrusted with maintenance.

 

Widetech reserves the right to change this dehumidifier's casing, circuit and parts without notice.

 

Important points on service, and operating safety, with a flow-chart for inspection and repair...........1

 

Troubleshooting …………………………………………………………..................................................2

 

Appearance and and functions of  this unit   ......................................................................................3

 

Technical specifications    ……………………………………………………….................... .. ...............4

 

Refrigerator system and schematic wiring Diagrams ………………................................................. ..5

 

Содержание NARCISO 12

Страница 1: ... Widetech reserves the right to change this dehumidifier s casing circuit and parts without notice Important points on service and operating safety with a flow chart for inspection and repair 1 Troubleshooting 2 Appearance and and functions of this unit 3 Technical specifications 4 Refrigerator system and schematic wiring Diagrams 5 ...

Страница 2: ...cing any electrical components they should be factory approved units Be sure that any electrical components are properly wired and in place FLOW CHART FOR INSPECTING AND REPAIRING THE UNIT Dehumidifier doesn t work Check if drain bucket water level switch is broken Electricity shutdown Check fuses on main switch Can not dehumidify Humidity switch is broken Check if air filter is clogged Humidity s...

Страница 3: ...ter is dirty Repair or replace Clean filter Detect the leakage and fill with refrigerant Normal Move to level place or use blocks Tighten screws Normal it is the sound when the refrigerant is flowing Clean filter Can not dehumidify or the dehumidifcation volume is too low Refrigerant is leaking Low temp and humidity Uneven floor Loud noise and vibration Motor or compressor is loose Sound of flowin...

Страница 4: ...en the water tank is full the full tank lamp will light up the dehumidifier will stop operating immediately BUCKET FULL LAMP BUCKET FULL LAMP When the lamp lights up which means dehumidifier is operating RUNNING LAMP RUNNING LAMP When operating under low temperature for a short period the dehumidifier will starting defrost process the indicating lamp will light up DEFROST LAMP DEFROST LAMP Dehumid...

Страница 5: ...220 240V 50Hz Capacitor WATER TANK CAPACITY POWER INPUT W UNIT 12 at 30 C 80 RH WIRE SPECIFICATION A MODEL POWER INPUT EVAPORATOR CONDENSER RxSxFPIxW RxSxFPIxW REFRIGERANT CAPILLARY mm Mm Kg COMP O L P F V 260 1 13 41 2 PHP 206 16A 250V H05VV F VDE 3G0 75mm 405W 632H 290D 13 5 35D020 B1 AADM 1 06 233 LS 16D1 01 30 8 450 MRA12279 12095 R 134a g 150 5 2 4 1R8S21FPI x 12 7mm 2R8S19FPI x 25 4mm D2 2 x...

Страница 6: ...R COMPRESSOR ASS Y FAN MOTOR SCHEMATIC WIRING DIAGRAM PTC HEATER 5 REFRIGERATOR SYSTEM DIAGRAM AC CORD WHITE BLUE BLUE FUSE T6 3AL 250V BROWN CMP FAN MOTOR CAPACITOR BLACK WHITE HUMIDITY SWITCH SENSOR RUN LAMP FULL LAMP DEFROST LAMP D6951 630 ...