Argo dados 9/13 Скачать руководство пользователя страница 2

 

12

V 01/12 

GENERAL OPERATING AND SAFETY INSTRUCTIONS 

 

  This appliance is a portable air-conditioner, designed for domestic use. 

  Only use this air-conditioner as described in this manual.  

  Ensure that the required voltage and frequency (220-240V/50Hz) match the available power source. 

  Ensure that the electricity system is able to deliver the operating current needed by the air-conditioner in addition to that 

normally absorbed by other appliances (electrical appliances, lighting, etc.). Please refer to the maximum absorption data 
given on the air-conditioner data plate. 

  Connection to the electricity grid must take place in accordance with current installation standards. 

  Ensure that the automatic switches and system protection valves are able to withstand start-up current of 10A (normally 

for less than 1 second). 

  The system socket must always be fitted with an efficient earth. 

  Make sure the plug is inserted fully. Do not use multiple adapters. Do not touch the plug with wet hands. Make sure the 

plug is clean. 

  Do not use the plug as a means by which to start/stop the air-conditioner: use the power button on the remote control or 

on the side control panel under the intake grille. 

  Do not install the air-conditioner in rooms that may be subject to water spray (e.g. laundries). 

  This appliance is not suitable for use by persons (including children) with reduced physical, sensory or mental abilities, or 

persons without the necessary experience and knowledge, unless they have been adequately supervised and instructed 
concerning the use of the appliance by a person responsible for their safety. 

  Before moving or cleaning, ensure that the device is unplugged from the socket.  

  Do not move the air-conditioner while it is operating; first turn the appliance off, check and remove any condensation that 

may have formed. 

  To turn the appliance off, set the remote control to OFF and remove the plug from the socket. Only pull on the plug. Do 

not pull the cord. 

 

Do not use the appliance if the cord or plug are damaged

. If the power supply cord is damaged, it must be replaced 

by the manufacturer, dealer or a similarly qualified person so as to avoid any safety risks. 

 

PRECAUTION! 

 

Do not insert any objects into the air-conditioner: this is very dangerous as the fan turns very quickly.

 

 

Ensure that air circulates freely around the unit. Do not cover the air intake and delivery grilles with drapes or in 
any way. 

 

WARNING! 

  The air-conditioner must be positioned 

at least 50 cm 

from the wall and any other obstacles, on a firm, flat surface to 

avoid water leaks. 

 

The air-conditioner is fitted with a system to protect the compressor from overload. This means that the 
compressor only starts once 3.5 minutes have passed from its previous stop.

 

 

Please wait at least 3.5 minutes before starting the unit. This helps prevent the compressor from being damaged.

 

 
WARNING! 
In the event of an anomaly, switch the appliance off and unplug from the socket. Do not dismantle or attempt to 
repair or modify the product. In the event of a malfunction, contact the after-sales service centre directly. 
 
WARNING! 

 

Do not expose the air-conditioner to direct sunlight, as the colour of the materials may change and if the 
appliance overheats, this may activate the protection mechanism, causing it to switch off. 

 

Do not use insecticides, oils, detergents or spray paints near the appliance; do not use aggressive chemical 
detergents to clean the casing: this may damage the finish and colour.

 

 

 

Close all open windows to maximise air-conditioning efficiency. 

 
The manufacturer will not be held liable if safety and accident prevention rules are not observed. 
 
 
 

 

Содержание dados 9/13

Страница 1: ...Read the instructions carefully before operating the appliance or carrying out maintenance work Observe all the safety instructions failure to observe the instructions may lead to accidents and or da...

Страница 2: ...while it is operating first turn the appliance off check and remove any condensation that may have formed To turn the appliance off set the remote control to OFF and remove the plug from the socket O...

Страница 3: ...OFF 1 6 sec ON 1 6 sec OFF Full Tank 1 CONTROL PANEL FUNCTION BUTTONS FOR OPERATION WITHOUT REMOTE CONTROL 2 3 TERMINAL CONNECTOR OF THE AIR EXPULSION TUBE 4 AIR EXPULSION TUBE 5 REMOTE CONTROL RECEIV...

Страница 4: ...distance of 50 cm from walls or other nearby obstacles Connect the connection 1 to the flexible hose 2 extend the hose as necessary to reach the outside and connect it to the back of the air conditio...

Страница 5: ...temperature set and when switched back on again it will retain this setting In this way fan speed can be adjusted the Timer Sleep function can be set 2 DEHUMIDIFICATION MODE Press FUNCT to select Deh...

Страница 6: ...imum dehumidification efficiency REMOTE CONTROL OPERATION Insert the batteries into the remote control respecting polarities specified Only use type AAA or IEC R03 1 5V batteries Remove the batteries...

Страница 7: ...perature desired in Cooling and Heating modes 2 Each time the button is pressed the temperature set increases by 1 C by holding the button pressed the temperature increases continuously Decrease 1 Ena...

Страница 8: ...tting will be cancelled and unit will start operating 2 Timer off auto off When the appliance is on set the time remaining before the unit is to switch on can be set Select a number of hours from 1 to...

Страница 9: ...th to clean the exterior surface of the air conditioner Do not use water that is too hot solvents petrol or other aggressive chemical compounds talcum powder or brushes these may damage the surface or...

Страница 10: ...RECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EUROPEAN DIRECTIVE 2002 96 EC When this appliance reaches the end of its useful life it must not be disposed of with household waste It must be delivere...

Отзывы: