Argo CRONO Скачать руководство пользователя страница 3

 

19 

V 12/19 

GENERAL OPERATING AND SAFETY INSTRUCTIONS  

 This appliance is a local air conditioner designed for domestic use. 

 Only use this air-conditioner as described in this manual.  

 Ensure that the required voltage and frequency (220-240V/50 Hz) 

match the available power source.  

 Fuse style 5ET or SMT 250V, the electricity passing through the 

fuse cannot be above 3.15A.  

 This appliance can be used by children aged from 8 years and 

above and people with reduced physical, sensory or mental 
capabilities or lack of experience and knowledge if they have been 
given supervision or instruction concerning use of the appliance in a 
safe way and understand the hazards involved. 

 Children shall not play with the appliance.  

 Cleaning and user maintenance shall not be made by children 

without supervision. 

 Ensure that the electricity system is able to deliver the operating 

current required by the air conditioner, in addition to that normally 
absorbed by other appliances (household appliances, lighting 
system, etc.). Please refer to the maximum power input data 
indicated on the air conditioner's data plate. 

 Connection to the electricity grid must take place in accordance with 

current installation standards. 

 Ensure that the automatic switches and system protection valves 

are able to withstand a start-up current of 6A (normally for less than 
1 second). 

 The system socket must always be fitted with an efficient earth 

connection. 

 Make sure that the plug is fully inserted. Do not use multiple 

adapters. Do not touch the plug with wet hands. Make sure that the 
plug is clean. 

Содержание CRONO

Страница 1: ...STRUCTIONS Read the instructions carefully before operating the appliance or carrying out maintenance work Observe all the safety instructions failure to do so may lead to accidents and or damage Stor...

Страница 2: ...ate the defrosting process or to clean the appliance in different ways other than those recommended by the manufacturer Should repair be necessary contact your nearest authorized Argoclima Service Cen...

Страница 3: ...shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Ensure that the electricity system is able to deliver the operating current required...

Страница 4: ...ged from the socket Do not move the air conditioner while it is operating first turn the appliance off check for any condensate build up and empty it if necessary To turn the appliance off set the rem...

Страница 5: ...nutes after its previous stoppage Please wait at least 3 minutes before starting the unit This helps prevent the compressor from being damaged WARNING In the event of an anomaly switch the appliance o...

Страница 6: ...AR VIEW 1 UPPER PANEL 8 BASE 2 CONTROL PANEL 9 UPPER FILTER 3 SIDE PLATE 10 CONTINOUS DRAINAGE HOLE DEHUMIDIFICATION 4 AIR OUTLET LOUVER 11 WRAPPING CORD 5 FRONT PANEL 12 AIR VENT 6 REAR PANEL 13 LOWE...

Страница 7: ...rated in the box below Infrared remote control Type AAA LR03 1 5 V batteries for remote control Not provided Flexible pipe inclusive of fitting for unit and end fitting for window Round fitting for wi...

Страница 8: ...e of the two leaves with the handle Rest the terminal connection on the fixed leaf bring the other leaf of the window close USE WITH WINDOW UNIT KIT 1 To make the hole in the glass it is advisable to...

Страница 9: ...he appliance leave it standing erect for at least two hours When switching between modes the fan continues to turn but the compressor stops the compressor will re start after 3 minutes This delay prot...

Страница 10: ...n and winter If used during summer it is best to leave the flexible pipe attached so that the hot air is discharged towards the outside rather than into the room During dehumidification continuous dra...

Страница 11: ...no sound is heard and the transmission symbol on the display does not flash the batteries must be replaced 11 If the system resets when the remote control button is pressed the electrical signal is p...

Страница 12: ...2 TIMER BUTTON 3 DOWN BUTTON 4 MODE BUTTON 5 UP BUTTON 6 FAN BUTTON 7 SLEEP BUTTON 1 ON OFF BUTTON 7 MODE BUTTON FAN 2 DOWN BUTTON 8 MODE BUTTON DEHUMIDIFICATION 3 UP BUTTON 9 MODE COOLING 4 SLEEP BUT...

Страница 13: ...t s not possible to select the ventilation speed therefore fan will forcefully choose the low fan speed MODE BUTTON 7 FAN 8 DEHUMIDIFICATION 9 COOLING When the unit is on press this button to choose t...

Страница 14: ...onto the air conditioner to clean it as this may damage its internal components or cause a short circuit 3 Storage When the air conditioner is not expected to be used for a long time clean the filter...

Страница 15: ...e re use recycling and other forms of recovery of such waste The appliance must be scrapped by a sorted waste disposal centre or by returning it to the retailer no charge is levied for this service wh...

Отзывы: