Argo Argoclima Magico Скачать руководство пользователя страница 9

9

If you have lost the remote control unit or it has troubles, follow
the steps below.

1. WHEN THE AIR CONDITIONER IS STOPPED

If you want to turn on the air conditioner push the operation but-
ton.

The  air  conditioner  will  start  in  automatic  fan  speed
The  temperature  setting  is  22

°

C  for  cooling  mode

and 28

°

C for heating mode.

NOTE

2. WHEN THE AIR CONDITIONER IS RUNNING

If you want to turn off the air conditioner push the operation but-
ton until the OPERATION lamp is turned off.

Power failure during operation.

In the event of power failure, the unit will stop. When the power
is resumed, the unit will restart automatically after 3 minutes.

NOTE

OPERATION  BUTTON

DO NOT:

Block the air intake and outlet of the unit. 
If  they  are  obstructed,  the  unit  will  not  work  well,  and  may
be damaged.

Let  direct  sunlight  into  the  room.  Use  sunshades, 
blind or curtain.

DO:

Always  try  to  keep  the  air  filters  clean.  A  clogged  filter 
will impair the performance of the unit.

To  prevent  conditioned  air  from  escaping,  keep  windows,
doors and any other openings closed.

The  flexible  tube  is  correctly  positioned  without  any  sharp
bends nor plies.

The room temperature is above 16

°

C for cooling and dehu-

midification mode.

WARNING

The blinking lamp (5) together with the stop of the air condi-
tioner indicate that the main condensate water tank is full.

If your air conditioner does not work properly, first check the
following points before requesting service.
If it still does not work properly, contact your dealer or service
centre.

Trouble:

the air conditioner does not run at all.

Possible cause:

1. Power failure.
2. Leakage breaker tripped.
3. Line voltage is too low.
4. Operation button is OFF.
5. Batteries in remote control unit have run down.

Remedy:

1. Restore power.
2. Contact service centre.
3. Consult your electrician or dealer.
4. Press the button again.
5. Replace batteries.

The use of portable telephones near the air conditioner may
cause  disturbance  to  its  normal  operation  and  must 
be  avoided.  In  case  abnormal  operation  is  noticed, 
(OPR operation lamp lights (3) but the air conditioner will not
run) to restore normal operation turn-off electric supply for 60
seconds  at  least,  by  disconnecting  the  main  switch  or  the
wall plug, then start again the air conditioner.

Trouble:

The air conditioner 

does not operate

and STANDBY

lamp flashes (4).

Possible cause:

1. Defective sensor.

Remedy:

1. Contact service centre.

Trouble:

TIMER lamp (2) flashes and the air conditioner does

not operate.

Possible cause:

1. Trouble in wiring system.

Remedy:

1. Contact service centre.

Trouble:

Compressor runs but soon stops.

Possible cause:

1. Obstruction of the air intake grilles.

Remedy:

1. Remove obstruction.

Trouble:

Poor cooling performance.

Possible cause:

1. Dirty or clogged air filters.
2. Heat source or many people in room.
3. Doors and/or windows are open.
4. Obstacle near air intake or air discharge port.
5. The set temperature on the remote control unit is too high.

Remedy:

1. Clean air filters to improve airflow.
2. Eliminate heat source if possible.
3. Shut them to keep the heat or cold out.
4. Remove it to ensure good airflow.
5. Set the right temperature on the remote control unit.

Trouble:

Clicking sound is heard from the air conditioner.

Possible cause:

1. During  operation,  any  plastic  parts  may  expand  or  shrink

due to a sudden temperature change. In this event, a click-
ing sound may occur.

Remedy:

1. This is normal, and the sound will disappear when an even

temperature is settled.

1

2

3

4

5

OPERATION WITHOUT THE REMOTE
CONTROL UNIT

TIPS FOR ENERGY SAVING

TROUBLESHOOTING

EG

Содержание Argoclima Magico

Страница 1: ...NSTRUCTIONS ISTRUZIONI D USO NOTICE D UTILISATION BEDIENUNGSANLEITUNG INSTRUCCIONES DE USO INSTRUC ES DE FUNCIONAMENTO 37 4252 008 2 06 2005 Save these instructions Conservate queste istruzioni Conser...

Страница 2: ...his equipment at your local community waste collec tion recycling centre In the European Union there are sepa rate collection systems for used elec trical and electronic products Please help us to con...

Страница 3: ...fuses etc are of sufficient capacity to handle a start up current of 20 A generally less then 1 second Do not install the air conditioner where it could be wetted by drops of water i e in laundries B...

Страница 4: ...han one month Press the SET and CLEAR buttons together after batteries replacement This operation allows you to reset correctly all the programs The remote control unit is to be set up again Replace t...

Страница 5: ...gh speed Medium speed Low speed Operation Mode Cooling Fan speed indication High speed Automatic fan speed Medium speed Low speed Dehumidification dry Displayed when data trasmitted Or remote control...

Страница 6: ...on will slightly differ from that described in the above tables ADJUSTING THE FAN SPEED AUTOMATIC Simply set the FAN SPEED selector to the position A microcomputer automatically controls the fan speed...

Страница 7: ...set for ON and OFF separately for two different time periods and they are effective two days only These timers will be effective on the day of setting and on the day after only At 24 00 on the second...

Страница 8: ...rear of the air conditioner Close with the inch the open end of the tube and tilting it towards the container let the condensate water flow At the end of the operations reinsert the discharge tube in...

Страница 9: ...is OFF 5 Batteries in remote control unit have run down Remedy 1 Restore power 2 Contact service centre 3 Consult your electrician or dealer 4 Press the button again 5 Replace batteries The use of por...

Страница 10: ...t with lukewarm soapy water then rinse in clean cold water and dry it before reinstallation 2 Cleaning of Casing and Grilles To clean the air conditioner wipe it with a clean soft cloth lightly moiste...

Отзывы: