Argo AGHP081PH Скачать руководство пользователя страница 1

 

 

 

 
 
 
 

 

 

 
 
 
 
 
 
 

 
 
 
 
 

 
 
 
 

 
 

 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 

 

 

 
 

Thank you for choosing an Argoclima heat pump. Please read this manual carefully before using the unit and retain
it for future reference.

 

V 09/21 

User Manual 

 

Air/water Heat pump 

Monobloc 

 

   MODELS: 
  

    

AGHP081PH       

  

   AGHP121PH    
   AGHP161PH    
   AGHP123PH    
   AGHP163PH 

Содержание AGHP081PH

Страница 1: ...ng an Argoclima heat pump Please read this manual carefully before using the unit and retain it for future reference V 09 21 User Manual Air water Heat pump Monobloc MODELS AGHP081PH AGHP121PH AGHP161PH AGHP123PH AGHP163PH ...

Страница 2: ... are only for reference 2 In order to make the product better we will continuously conduct improvement and innovation We have the right to make necessary revision to the product from time to time due to the reason of sales or production and reserve the right to revise the contents without further notice 3 For personal injury or property loss and damage caused by improper operation such as improper...

Страница 3: ...3 2 Operation Instructions 4 2 1 ON OFF 4 2 2 Function Setting 4 2 3 User Parameter Setting 13 2 4 Commissioning Parameter Setting 14 2 5 Viewing 24 2 6 General Setting 28 3 Intelligent Control 29 3 1 Install Ewpe Smart APP 30 3 2 Setting of Main Functions 34 3 3 Setting of Other Functions 35 ...

Страница 4: ......

Страница 5: ...RECTIVE 2012 19 EU This appliance may not be scrapped with domestic waste at the end of its life cycle We call your attention to the crucial role played by the consumer in the re use recycling and other forms of recovery of such waste The appliance must be scrapped by a sorted waste disposal centre or by returning it to the retailer no charge is levied for this service when you purchase a new equi...

Страница 6: ...ll be displayed based on the mode and status of the controller No Item Description 1 Current mode Current mode 2 Data Current data 3 Time Current time 4 Function setting Go to the user setting page 5 Parameter setting Go to the parameter setting page 6 Parameter viewing Go to the parameter viewing page 7 Commissioning parameters Go to the commissioning parameter setting page 8 ON OFF It is used to...

Страница 7: ...r Error Icon Notes At any other page where there is no operation in 10 minutes the display panel will back to the menu page 1 2 Backlight Among the general setting page when Back light is set to Energy save the display panel will light off when there is no operation in 5 minutes However it will light on again by touching any valid area When Back light is set to Lighted the display panel will be ke...

Страница 8: ... function setting page by touching the page turning key it will access to the last or next page When setting is finished by touching the homepage icon it will directly back to the homepage by touching the back icon it will back to the upper menu 3 At the function setting page by pressing the desired function it will access to the corresponding setting page of this option 4 At the function setting ...

Страница 9: ...ff 7 Weather depend On Off Off 8 Weekly timer On Off Off 9 Holiday release On Off Off 10 Disinfection On Off Off When the water tank is unavailable it will be reserved The disinfection date ranges from Monday to Sunday Saturday is defaulted 23 00 The disinfection time ranges from 00 00 23 00 23 00 is defaulted 11 Clock timer On Off Off 12 Temp timer On Off Off 13 Emergen mode On Off Off 14 Holiday...

Страница 10: ...ank is available When the water tank is unavailable this function will be reserved It will be memorized upon power failure 2 2 3 Cool hot water Operation Instructions At the function setting page with the unit turned off by touching Cool hot water the display panel will go to the corresponding setting page where desired option can be selected Then by pressing OK this setting will be saved and the ...

Страница 11: ...n only be canceled manually It will be memorized upon power failure 2 2 6 Weather Depend Operation Instructions At the function setting page by touching Weather depend there will be a choice box where it is able to set it to On or Off and also it is able to set the weather dependent temperature Page of the Weather Depend Notes When Weather depend has been activated it cannot be deactivated by ON O...

Страница 12: ...the current mode and temperature setting Timer setting for the weekday Valid it indicates this setting works only when Weekly timer has been activated unaffected by the holiday mode Invalid indicates this setting does not work even though the Weekly timer has been activated It will be memorized upon power failure 2 2 8 Holiday Release Operation Instructions At the function setting page by touching...

Страница 13: ...matter if the unit is turned on or off This mode will take priority over the Hot water mode When disinfection operation fails the display panel will tell Disinfection fail Then by pressing OK it will be cleared When Disinfection has been activated if communication error with the indoor unit or malfunction of the water tank heater occurs it will automatically quit It will be memorized upon power fa...

Страница 14: ...d Cool are allowed When the end time is earlier than the start time this setting is invalid Water tank temperature can be set only when Hot water is involved in the operation mode The setting of Clock timer only works once If this setting is needed again it should be set again It will be deactivated when the unit is turned on manually This function will be memorized upon power failure 2 2 11 Temp ...

Страница 15: ...e is set to Heat if Other thermal or Optional E Heater is set to Without the unit will fail to access to the Emergen mode When the unit performs Heat under Emergen mode and the controller detects HP Water Switch Auxi heater 1 Auxi heater 1 and Temp AHLW this mode will quit at once In the same way when errors mentioned above occur Emergen mode cannot be activated When the unit performs Hot water un...

Страница 16: ...eriod can be set to Valid or Invalid The option Mode is used to preset the mode WOT Heat is used to set the leaving cold hot water temperature Start timer End timer is used to for time setting After that by touching the Save icon all settings will be saved Notes When Preset mode has been set to Hot water and Water tank is to set to Without the preset Hot water mode will be automatically switched t...

Страница 17: ... page by touching Reset a choice box will pop up where by touching OK all user parameter settings will be reset and by touching Cancel it will back to the function setting page Notes This function is allowed only when the unit has turned off This function is valid for Temp timer Clock timer Preset mode Weekly timer and Weather depend 2 3 User Parameter Setting Operation Instructions 1 At the menu ...

Страница 18: ... RT Cool 18 30 C 64 86 C 24 75 C 4 Room temperature for heating T4 RT Heat 18 30 C 64 86 C 20 68 C 5 Water tank temperature T5 T water tank 40 80 C 104 176 C 50 122 C 6 Leaving water temperature difference for cooling Δt1 ΔT Cool 2 100 C 36 50 C 5 41 C 7 Leaving water temperature difference for cooling Δt2 ΔT Heat 2 10 C 36 50 C 10 50 C 8 Leaving water temperature difference for water heating Δt3 ...

Страница 19: ...en it is set to Without hot water by the solar kitting is unavailable 6 Water tank With Without Without 7 Thermostat Without Air Air hot water Without This setting cannot be interchanged between Air and Air hot water directly but via Without this option Each time when Air or Air hot water is switched to Without the unit will go to the OFF status Meanwhile the control will send out OFF command for ...

Страница 20: ...t run time Heat run time 1 10min 3min 2 way valve Off 5min 2 way valve On 2 4 1 Ctrl state Operation Instructions At the commissioning parameter setting page by touching Ctrl state it can be set to T water out or T room Notes When Remote sensor is set to With this setting can be set to T water out or T room When Remote sensor is set to Without this setting can only be set to T water out This setti...

Страница 21: ...be done no matter if the unit is turned on or off This setting is allowed only when the water tank is available When the water tank is unavailable this setting will be reserved It will be memorized upon power failure 2 4 4 Water Tank Operation Instructions At the commissioning parameter setting page by touching Water tank the control panel will access to the corresponding setting page where Water ...

Страница 22: ...nel see Section 2 2 3 and 2 2 4 for more details The status of the thermostat can be changed only when the unit is turned off When it has been activated Weekly timer Clock timer Temp timer and Preset mode cannot be activated at the same time This setting will be memorized upon power failure 2 4 6 Other Thermal Operation Instructions 1 At the commissioning parameter setting page by touching Other t...

Страница 23: ...thermal will start Under the Heat Hot water mode the other thermal only works for space heating and the electric heater of the water tank works for water heating In this case the 2 way valve is controlled base d on the setting of the control panel and the 3 way valve will always stop During heating operation the water pump of the heat pump unit will be stopped however during standby status the wat...

Страница 24: ... will access to the corresponding setting page 2 At the setting page Floor debug Segments Period 1 temp Segment time and ΔT of segment can be set No Full Name Displayed Name Range Default Accuracy 1 Floor debug switch Floor debug On Off Off 2 Quantity of segments Segments 1 10 1 1 3 Temperature of the first segment Period 1 temp 25 35 C 77 95 C 25 C 77 C 1 C 4 Duration of each segment Segment time...

Страница 25: ...will quit when the defrosting temperature goes to 20 C or the defrosting duration is equal to 10 minutes 2 4 12 Force Mode Operation Instructions 1 At the commissioning parameter setting page by touching Force mode the control panel will access to the corresponding setting page 2 At the Force mode setting page it can be set to Force cool Force heat and Off When it is set to Force cool or Force hea...

Страница 26: ... Recovery Operation Instructions At the commissioning parameter setting page by touching Refri recovery it will access to the refrigerant recovery page When Refri recovery is set to On the control panel will go back to the home page At this time any touch operation except ON OFF will get no response with a prompt dialog box popping up saying The refrigerant recovery is running By touching ON OFF r...

Страница 27: ...l this setting will not be saved and quit No Full Name Display Name Range Default Remark 1 T HP max T HP max 40 55 C 104 131 C 50 C 122 C 2 Cool run time Cool run time 1 10min 3min 2 way valve Off When Cool run time has expired and temperature difference keeps at the standby zone the unit will stop 5min 2 way valve On 3 Heat run time Heat run time 1 10min 3min 2 way valve Off When Heat run time ha...

Страница 28: ...unit Unit status Cool Heat Hot water Off 4 Status of the water pump HP pump On Off 5 Status of the water tank heater Tank heater On Off 6 Status of the 3 way valve 1 3 way valve 1 NA 7 Status of the 3 way valve 2 3 way valve 2 On Off 8 Status of the compressor crankcase heater Crankc heater On Off 9 Status of the heater 1 for the main unit HP heater 1 On Off 10 Status of the heater 2 for the main ...

Страница 29: ...T suction 3 Discharge temperature T discharge 4 Defrosting temperature T defrost 5 Entering water temperature of the plate type heat exchanger T water in PE 6 Leaving water temperature of the plate type heat exchanger T water out PE 7 Leaving water temperature of the auxiliary heater T optional water Sen 8 Water tank temperature T tank ctrl 9 Floor debug target temperature T floor debug 10 Floor d...

Страница 30: ...r between the display panel and indoor main board IDU Com E6 High pressure sensor error HI pre sens Fc Leaving water temperature sensor error for the plate type heat exchanger of the heat pump Temp HELW F9 Leaving water temperature sensor error for the auxiliary electric heat of the heat pump Temp AHLW dH Entering water temperature sensor error of the plate type heat exchanger of the heat pump Tem...

Страница 31: ...rresponding phase U and or phase V Sensor con Pd Communication error between the display panel and the outdoor unit ODU Com E6 Refrigerant vapor line temperature sensor error Temp RGL F0 Refrigerant liquid line temperature sensor error Temp RLL F1 Water tank temperature sensor error NA for mini chillers Tank sens FE 4 way valve error 4 way valve error U7 Jumper cap error Jumper cap error C5 2 5 4 ...

Страница 32: ...ory Beeper Back light Time Date and Language General Setting Page General Settings No Item Range Default Remarks 1 Temp unit C F C 2 On Off memory On Off On 3 Beeper Enter On 4 Back light Lighted Energy save Energy save Lighted the control panel will always light on Energy save When there is no touching operation in 5 minutes the control panel will be lighted off automatically but will light on ag...

Страница 33: ...NERAL setting page Time Data Page 3 Intelligent Control Notes Make sure the smart phone or tablet computer adopts standard Android or Ios operation system For detailed version please refer to the APP The Wi Fi function doesn t support Chinese Wi Fi network name The devices can be connected and controlled only in Wi Fi and 4G hotspot modes Router with WEP encryption is not supported Software operat...

Страница 34: ...he following QR code with your smart phone to download and install Ewpe Smart APP directly 2 Open Ewpe Smart APP and click Sign up for registration 3 Except sign in in the prompt interface you can also enter the homepage and click the profile picture at the left upper corner to sign in ...

Страница 35: ...Operation Instructions 31 4 Click at the right upper corner of homepage to add device ...

Страница 36: ...Operation Instructions 32 After selecting AC you can select different reset tools according to actual situation The APP interface will provide relevant operation instructions for different tools ...

Страница 37: ...ly Wi Fi password shall be input Or after setting and energizing the air conditioner click Add appliance manually at the right upper corner to select the wireless network for controlling the device Then confirm family Wi Fi and arrange configuration After accomplishing device reset and filling correct information search device and arrange configuration ...

Страница 38: ...36 3 2 Setting of Main Functions 1 Set mode and temperature ...

Страница 39: ...t the left lower corner in device operation interface to enter advanced settings 3 3 Setting of Other Functions Click the profile picture at the left upper corner of homepage and set each function in the following menu ...

Страница 40: ...36 3 3 1 Home management Click Home management to create or manage family You can also add family members according to the registered account ...

Страница 41: ...37 3 3 2 Help Click Help and view the operation instructions of the APP 3 3 3 Feedback Click Feedback to submit feedback ...

Страница 42: ...36 www argoclima com ...