WARNING

Clean the air conditioner with a  soft  and  dry 
cloth. Do not use chemical solvent,insecticide,
 Inflammable-spraying  material or which da-
mage the appearance of air conditioner for c-
leaning.

Do not put  burning  appliances  at  the  place 
where   can   be  blown   directly   by  the   air,
insufficient burning may occur.

Do not install the air conditioner in where leak 
flammable gas. If  there  is  electrical  leakage 
accidentally from air conditioner, it  is  easy to 
cause fire or explosion ,as is very dangerous.

Stop operation and unplug power cable imm-
ediately if abnormality is found ( burned smell
etc ).

Do not use for special purposes. Do not use to
store precision equipment,food,painting etc, w-
hich are required humidity and temperature, for
 their quality may be affected.

Close doors and windows ( better using cont-
ains )while operating air conditioner for a long 
time,if room air is quite turbid,you  should  open  
a door and window for a moment  to get some 
outdoor fresh air.

Do not operate  air conditioner  at COOL/DRY
mode  for  a   long  time  under  high  humidity 
( above 80%), if door/window is open or under 
high  humidity  condition,  condensation   may 
drop from the unit.

Do not install, service or move the  Air Conditioner  on  your  own. Improper  process  can  cause  fire, 
electric shock, the falling unit can injure people or water leakage. Contact our air conditioner specially 
engaged service center.

SAFETY AWARENESS

 The appliance shall be installed in accordance
  with national wiring  regulations.

      The appliance must not be installed in the laundry.
      The appliance must be installed 2.3m above 
      the floor.
      An all-pole disconnection device which has at
      least 3mm separation distance in all pole shall
      be in corporated in the fixed wiring according 
      to the national rule.

Содержание AGE52RH U.E.

Страница 1: ...k you for choosing an Air Conditioner Please read this OWNER S MA NUAL carefully prior to using keep it for further reference OWNER S MANUAL SPLIT AIR CONDITIONER WALL MOUNTED TYPE AGW52RH U I AGE52RH...

Страница 2: ...or Parts Safety Awareness Operation procedure Remote Controller s Preparative Before Operation Operation Explanations of Air Conditioner Service and Maintenance of the Air Conditioner Fault Confirmati...

Страница 3: ...ulti hole sockets Possible fire electric shock may occur for poor connection bad insulation and excessive allowable current Do not plug power cable when in operation Spark may appear and cause fire Pu...

Страница 4: ...oors and windows better using cont ains while operating air conditioner for a long time if room air is quite turbid you should open a door and window for a moment to get some outdoor fresh air Do not...

Страница 5: ...ir inlet Manual operation open the Front panel INDOOR UNIT Time indicator Sleep indicator Run indicator Power supply cord Deflector Left Right deflector SWING SWING MANUAL MANUAL OFF OFF ON ON CANCEL...

Страница 6: ...T BUTTON RUN STOP BUTTON FAN SPEED BUTTON SLEEP BUTTON RESET PIECE TIME SET BUTTON TIME CANCEL BUTTON TIME ON BUTTON TIME OFF BUTTON OPERATION MODE BUTTON MANUAL SWING BUTTON SWING BUTTON NOTICE REMOT...

Страница 7: ...ly short two RESET piece it will operate normally Remove batteries if Remote controller has not been used for a long time When the button is pressed indoor unit will beep once or twice indicating the...

Страница 8: ...er s display Sleep selection Press SLEEP button set sleep operation and cancel when repressed 3 3 Fan speed adjustment Press FAN SPEED button change the fan speed of indoor unit in the order of low me...

Страница 9: ...ngers Fig 1 Left Right deflector ADVICE In DRY or COOL mode advise to make the Fan speed with auto air blows downward in 1 In HEAT mode advise to make the Fan speed with auto air blows downw ard in 4...

Страница 10: ...e Press MAUNAL SWING button or SWING button to change up down air flow direction Press FAN SPEED button to change the fan speed of indoor unit Press TEMPERATURE ADJUSTMENT button to change the setting...

Страница 11: ...nter time setting press button or button Untill set time and timer operation goes off press If you want or will disappear on the remote controller display ON Press button Remote Controller display whe...

Страница 12: ...ed dirt may cause fire FAN OPERATION Take the batteries out of the remote controller Want to use the Air Conditioner Clean filters and replace them to origi nal position Clean indoor unit with soft cl...

Страница 13: ...then push down and close front panel Clean deodorization filters and air cleaner Take out filters first then take out deodorization filter and air cleaner Clean deodorization filter air clean er with...

Страница 14: ...Air will not immediately blow out at the start of HEAT mode It is processing information air will only blow out when sufficiently warm Please wait This is a way to protect compressor as per microproc...

Страница 15: ...opping on the heat exchanger Melting sounds of frost on heat exchanger Indoor unit issue pooosh sound and click sound Click sound of fan or compressor when switc hing ON OFF pooosh sound of refrigeran...

Страница 16: ...cting cable is damaged it must be replaced by the manufacturer or its service agent or similar qualified person in order to avoid a hazard C Indoor side DB WB Maximum cooling Minimum cooling Maximum h...

Страница 17: ...hose high front right back underside left back left back Configuring pipe can be installed to back right underside or left back side Cover connecting pipe with heat isolating material the thickness o...

Страница 18: ...m wall to avoid any vibr ation Avoid direct sunshine Easy to drain condensate water Do not make any interference caused by the fluorescent lamp to the remote controller s signal Minimum distance betwe...

Страница 19: ...of wall post etc fasten string at the central hole 175mm or more from sidewall 245mm or more at least 60mm from sidewall mounting plate plumb NOTICE The holes at solid arrow position must be secured t...

Страница 20: ...owed after refit it would lead to water leak Arrangement of drain hose To eject the condensate water easily the drain hose should be declined downward The arrangement in diagram2 5 is wrong If the dra...

Страница 21: ...e The connecting cables must be clipped together 1 7 7 Wiring 1 1 1 Flaring the pipe end 1 2 2 Cut the pipe using a pipe cutter Raughness Remove burrs at the tip of the pipe cut Reamer Burr Insert a f...

Страница 22: ...ench Fig 2 Open the valve of the low pressure and close high pressure valve of manifold gauge Purge the air from the system using the vacuum pump until its pressure low pressure side is below 12Pa Clo...

Страница 23: ...nly type add amount A Lm 7m 15g m Heat pump type add amount A Lm 7m 50g m A add refrigerant amount L the length of connecting pipe 1 4 4 7 0 0 8 15 50 9 30 100 10 45 150 the length of connecting pipe...

Страница 24: ...Via Varese 90 21013 Gallarate VA Italy Phone 39 0331 755 111 Fax 39 0331 766 240 www argoclima com...

Отзывы: