![Argo AER507SC Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/argo/aer507sc/aer507sc_technical-and-service-manual_2967459035.webp)
32
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 220 – 240V ~ 50Hz
Rating Conditions Running Amps. A 0.13 /
0.14 0.30
/
0.32 5.8 / 5.7 6.2 / 6.2
Power Input kW 0.029 / 0.033 0.066 / 0.076 1.23 /
1.26 1.32 /
1.37
Full Load Conditions Running Amps. A 0.13 /
0.14 0.30
/
0.32 7.2 / 7.0 7.6 / 7.4
Power Input kW 0.029 / 0.033 0.066 / 0.076 1.51 /
1.55 1.61 /
1.66
Rating Conditions : Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit AWR512CL
Outdoor Unit AER512SC
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 220 – 240V ~ 50Hz
Rating Conditions Running Amps. A 0.11 /
0.12 0.25
/
0.27 3.8 / 3.6 4.2 / 4.0
Power Input kW 0.025 / 0.029 0.054 / 0.063 0.83 /
0.85 0.91 /
0.94
Full Load Conditions Running Amps. A 0.11 /
0.12 0.25
/
0.27 4.6 / 4.3 5.0 / 4.7
Power Input kW 0.025 / 0.029 0.054 / 0.063 1.01 /
1.02 1.09 /
1.11
Rating Conditions : Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit AWR509CL
Outdoor Unit AER509SC