![Argo AE2MI56AH Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/argo/ae2mi56ah/ae2mi56ah_installation-instructions-manual_2967439021.webp)
Fig. 34a
Fig. 34b
Fig. 35
Fig. 36
Indoor unit
R.OUT connector
on circuit board
Indoor unit
extended-connection
cord (8 m):
Available separately
STK-WS0508W
Remote controller
IN connector
Indoor unit
5. Address Setting of the Remote Control
Unit
5-1. Setting the Remote Controller Address
The address can be set in order to prevent interference
between remote controllers when two Sanyo A/C units
are installed near each other. The address is normally
set to “A.” To set a different address, it is necessary to
change the address on the second remote controller.
(1) Break the address-setting tab “A” on the second
remote controller to select the remote controller
address “B.” (Fig. 34b)
(2) Insert dry-cell batteries into the second remote con-
troller and press the reset button. Then reattach the
cover.
(3) Open the air intake grille on the second indoor unit.
Move the operation switch to the “DEMO” position.
(Fig. 35)
(4) Press the Start/Stop button on the remote con-
troller. Check that the “beep” signal-received sound
is heard from the second indoor unit.
(5) Move the operation switch to the “ON” position, and
close the intake grille. (Fig. 35)
(6) Operate the remote controller. Check that the
“beep” signal-received sound is heard from the sec-
ond indoor unit.
5-2. Operating Multiple Indoor Units with a Single
Remote Controller
Insert the indoor unit extended-connection cord (avail-
able separately) into the R.OUT connector on the
indoor unit circuit board. Insert the other end into the
indoor unit remote controller IN connector. Repeat this
procedure. A total of up to four units can be controlled.
Be sure as part of the test run to check the installa-
tion using the Installation Check Sheet (next page).
19
Pin
Case