![Argo 387006112 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/argo/387006112/387006112_technical-data-and-service-manual_2967418006.webp)
AS28AL
AS38AL
Controller PCB
Part No.
Controls
Control circuit fuse
Remote Control Unit
Fan & Fan Motor
Type
Q'ty ……. Dia. and lenght
mm
Fan motor model…Q'ty
No. Of poles…rpm (230 V)
Running Amps
A
Power input
W
Coil resistance (Ambient temp. 20 °C )
Ω
BLU-BLK: 231,0
BLK-GRY: 50,2
GRY-RED: 27,8
RED-WHT: 119,5
WHT-BLU: 49,5
Safety devices
Type
Operating temp. Open
°C
Close
°C
Run capacitor
µF
VAC
Flap Motor
Type
Model
Rating
No of poles …rpm
Nominal output
W
Coil resistance (Ambient temp. 20 °C )
k
Ω
Heat Exch. Coil
Coil
Rows
Fin pitch
mm
face area
m2
DATA SUBJECT TO CHANGE WITHOUT NOTICE
KSA
Microprocessor
250 V - 5 A
RC-7 (RC)
Centrifugal fan
1…. Ø 280 / L 175
R4E280-AK45-12…1
4 … 870/720/600/270
0,33
75
Internal thermal protector
160 ± 10K
130 ± 15K
2
450
Synchro motor
M2LJ24ZE31
AC 208/230V 50/60Hz
8 …. 2,5/3,0
1,3
0,258
3/2,5
16,45 ± 15%
Aluminium plate fin / Copper tube
1
6
Содержание 387006112
Страница 8: ...2 DIMENSIONAL DATA Units mm 8 ...
Страница 9: ...3 ELECTRICAL DATA 3 1 Electric Wiring Diagrams 9 ...
Страница 10: ...4 1 Cool Mode Operation 4 FUNCTION 10 ...
Страница 11: ...4 2 Heat Mode Operation 11 ...
Страница 12: ...4 3 Auto Cool Heat Mode Operation 12 ...
Страница 13: ...4 4 Dry Mode Operation 13 ...
Страница 15: ...2 Outdoor Coil High Pressure Protection 15 ...
Страница 16: ...4 7 Protection Operations in Heat Mode 1 Outdoor Coil Deice Protection 16 ...
Страница 17: ...17 ...
Страница 18: ...2 Indoor Coil High Pressure Protection in Heat Mode 18 ...
Страница 19: ...4 8 Sleep Function 4 9 Daily Timer Function 4 10 IFEEL Function 19 ...
Страница 32: ...Via Varese 90 21013 Gallarate Va Italy Tel 39 0331 755111 Fax 39 0331 776240 www argoclima it ...