5-2 Cool Mode Operation
In Cooling Mode, the operation of the compressor (CM), Outdoor Fan (FMO) and Indoor Fan (FMI) are
determined by:
1) the difference between the room air temperature (RAT) and the set point temperature (SPT)
2) the protection level at which the system is operating
3) the thermal load in the room
NOTES
In addition to the temperature difference of above, the operation of the main components (CM, FMO,
FMI) is also controlled by protection function.
The minimum off time of compressor is 3 minutes.
The indoor fan can change speed only after it has operated at the same speed for 30 sec if in AUTO
and 1 sec for the other settings (High, Med, Low).
5-3 Heat Mode Operation
The Heating mode operation is similar to the Cooling mode operation. The CM, FMO and FMI are
controlled by the same parameters.
The FMI will not be turned on until the indoor coil temperature is warm enough to prevent the supply of
cold air (see COLD DRAFT PREVENTION feature for details).
The indoor fan can change speed only after it has operated at the same speed for 30 sec if in AUTO
and 1 sec for the other settings (High, Med, Low).
11
Содержание 387005002
Страница 7: ...2 DIMENSIONAL DATA FCIAS8 Units mm Wide Tube Ø 9 52 3 8 7 ...
Страница 8: ...3 PERFORMANCE DATA 3 1 Air Throw Distance Chart FCIAS8 Floor Mounted Ceiling Mounted 8 ...
Страница 9: ...4 ELECTRICAL DATA 4 1 Electric Wiring Diagram 9 ...
Страница 24: ...7 4 OUTDOOR UNIT DOES NOT RUN AND NO FAULT IS DISPLAYED 7 5 ONLY OUTDOOR UNIT IS OFF 24 ...
Страница 28: ...7 8 NOISE PROBLEM 28 ...
Страница 30: ...Via Varese 90 21013 Gallarate Va Italy Tel 39 0331 755111 Fax 39 0331 776240 www argoclima com ...