www.argo-hytos.com
15. Technical data
15.1 Device dimensions
Fig. 9: Device dimensions
15.2 Technical data
Nominal flow rate (50Hz)
l/m
40
Pressure limiting valve
bar
7 ± 1
Max. operating pressure
bar
8
Filter element
V7.1230-153
β
3
(c)
≥
200
Clogging indicator
electric
DG 041-32
2,5 bar switch-on point
Electric drive
3~400V 1,5 kW
n = 1.500 min
-1
50 Hz
n = 1.800 min
-1
60 Hz
Tare weight
kg
approx. 30
Sound power level
db(A) max. 72 (under operating conditions permitted for continuous operation)
77 (under operating conditions permitted for short-term operation)
Device dimensions
(length x width x height)
mm
see chapter 15.1
Table 8: Technical data