Subject to change · 33143400 · 05.2016 · EN
Page 10
www.argo-hytos.com
5. About this product
5.1
Performance specification
The filter unit FA 008 is a mobile filter unit for filtration of hydraulic fluids and lubricants with a viscosity of 15 mm
2
/s - 200 mm
2
/s
(in continuous operation) in the bypass flow (400 mm
2
/s max. in short-term operation).
A separate installation in the bypass or cooling circuit for fine filtration and discharge of the full flow filter is just as possible as the
filtration of fresh oil and the cleaning (flushing) of polluted systems for wear protection of components and systems.
The volume flow is 8 l/min (50 Hz).
The operating temperature is in the range of 0° C to 65° C.
5.2
Device description
The filter unit FA 008 consists of a support frame in which a filter pump unit is integrated. This consists of an electrically operated
filter pump with exchangeable filter element and a gauge as maintenance indicator.
The on/off switch is located in the control box of the pump motor. The suction hose is connected to the suction port of the pump
and the pressure hose at the output of the main filter.
5.3
Component overview
1
Clogging indicator
6
Electric motor
2
Pressure hose
7
Power supply cable
3
Discharge pipe
8
Suction hose
4
On/off switch
9
Filter housing with filter element
5
Suction bell
10
Filter cover
Fig.1: Component overview
1
2
3
4
10
9
8
7
6
5