![Argo-Hytos EL7-EA Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/argo-hytos/el7-ea/el7-ea_instruction-manual_2967768011.webp)
EL7-I_Instructions_Hinweise_Pokyny_19151_3en_de_cz_07/2022
Page 11
www.argo-hytos.com
Logging in to the application:
After clicking on the selected unit, a login window for entering the password will be displayed.
The default password was set to
1234
by the manufacturer.
The password can be changed in the application, see Changing the password on page 18.
After clicking
Login
, a connection will be made to the electronics, which will no longer be visible
to other devices and it will not be possible to connect to it from another device. The blue LED will
be lit continuously.
Caution!
The button is located directly on the electronics motherboard, use a non-conductive object
to press the button. Any contact of a conductive object with the electronics board around
the button, can damage or destroy the electronics.
The forgotten password can be deleated by holding the “Configuation button” on
the front panel of the electronics. The button must be held for 10 s or more until the
blue LED flashes, the password is then set to 1234 again.
See page 5 for access and location of the „
Configuration button
“.
By removing the lid, the electronics lose primary protection against moisture and dirt,
it is necessary to ensure that neither mositure nor dirt get inside during use
of the “
Configuration button
“. Leave the lid removed only for the necessary length
of time and refit as soon as possible.
Caution!
There is a seal around the perimeter of the lid and under the screw, which must remain
intact after removal and return of the lid on the electronics and the rim surfaces must be
clean. Otherwise, the seal will not perform its function properly, moisture and dirt may enter
the electronics and cause destruction.
Status of electronics:
The information window gives a basic overview of the electronics status, the level of the command signal,
the current and required current to the coils, the supply voltage, the processor temperature and the running
time of the electronics. If the limits are exceeded, an error message describing the source and cause of
the error will be displayed. When the error condition is cleared, it automatically returns to the operating
state, the errors do not need to be acknowledged or related in any way. See possible error conditions. page 21.
Enabling this function allows you to control input signal in specific range from 0…100% for one solenoid
valves or -100%...+100% for double solenoid or bipolar valves. Control can be performed by manually
entering a permanent value or by using the built-in signal generator.
Manual control is deactivated by a switch in the application, is automatically cancelled when the application
is closed or the Bluetooth connection is interrupted.
Manual control:
Caution!
During manual control, the electronics do not respond to the analog control input signal.