- 7 -
8.-
Input 12V DC power adapter (included).
3.2
Starting
1.-
After connecting the power to the instrument, the message
“Initial….” “Please Wait...”
appears for 37 seconds.
2.-
Then the message
“K
eyboard Locked
”
appears. To access to the configuration menus
the user has to enter a password.
3.-
Press
ENTER
.
4.-
The field
“
Enter Password
”
appears. Enter the access code. (By default: 0000).
5.-
Press
ENTER
.
6.-
The field
“Network Setting” appears, this is the first option on
the configuration menu.
3.3
Configuration menu
1.-
Frequency:
It sets the frequency value for the output signal.
Important:
Check that the
selected frequency is not already being used by a current television distribution channel.
2.-
RF Level Adj:
It adjusts the power level of the output signal, in dB units. Its range from 0 to -30
dB.
3.-
Bandwidth:
Channel bandwidth. (6, 7 , 8 , 7 - 8 MHz).
4.-
FFT Carriers:
Signal transmission mode. (2K, 8K).
5.-
Guard Interval:
Safety signal margin. (1/4, 1/8, 1/16, 1/32).
6.-
Constellation:
Constellation type used to transmit signal(QPSK,16QAM, 64QAM).
7.-
Code Rate:
Available values are (1/2, 2/3, 3/4, 5/6, 7/8).
8.-
Video Output:
Video encode. H.264 of the video output.
9.-
Audio Output:
Audio encode. Selection between MPEG-2 and AAC
10.-
Video Bitrate:
Select video bit rate(2,4,6,8,10,12 Mbit/S).
11.-
Audio Bitrate:
Bitrate to encode the audio. Available values are between 192 kbit/s.
12.-
Service Name:
Service name edit.
13.-
Provider Name:
Service provider name edit.
14.-
Service ID:
Service ID edit.
15.-
LCN
: It specifies the index for the service sorting on the digital terrestrial television
receiver. Values are between 1 and 999.
16.-
Country:
Country selection for LCN sorting.
17.-
Original Net ID:
Identifier of the original network. It is the number to identify the network
from where the signal comes.
18.-
Network ID:
It is the number that identifies the network where the signal is distributed.
19.-
Network Name:
Network name edit.
20.-
TS ID:
It is the transport stream identifier.
21.-
NIT Version:
Network Information Table version. In some countries it should match with
other tables version received from the receiver.
22.-
Information:
It shows the firmware version installed in the instrument. This option is not
editable.
23.-
Apply Setting: