The electric hoist has an overheating protection. If the device stops from overheating, you
have to wait for it to cool down before operating again. Therefore, one should avoid the too
frequent jog mode when the device is running under load.
•
The ambient temperature should be between 5-40 ° C. The height above sea level should be
less than 1000m. The ambient humidity should be 30-95%. The temperature for storage and
transport is -25 to 55 ° C.
•
According to the requirements of EN60204-32: 2008, test 2 in chapter 18.2.2 must be carried
out by the end user after installation.
8.
Problem solving
Common Malfunction
Cause
Solution
The up/down switch is
used, but the motor
does not turn.
1.
It is not plugged into the
power supply.
2.
The wires are broken or
ripped.
3.
Switch malfunction.
4.
The capacitor is burned
through.
5.
End-switch has not been reset
or a switch error.
6.
The thermal switch has
suffered a wire break.
1.
Connect the item to the power
supply.
2.
Check the wires and plug it in
again to the outlet.
3.
Repair the switch or change it.
4.
Change your capacitor.
5.
Check the end-switch and
replace the limit switch.
6.
Wait until the item cools down
or replace the thermal switch.
The dual-direction
switch has been
activated. The motor is
very loud, can however
not pick-up the load.
1.
The voltage offered is too
small.
2.
The capacitor is damaged.
3.
The brake is not completely
open.
1.
Adjust the voltage, depending
on the power supply.
2.
Change the capacitor.
3.
Allow the machine to be
repaired by a qualified repair
service.
After a power loss, the
brakes do not hold or
the machine slips down.
1.
The air between the brakes is
too large.
2.
The brake spring is ripped.
3.
The brake disk is locked.
4.
The brake disk is too dirty.
Allow the machine to be repaired
by a qualified repair service.
The noise of the
machine becomes
louder.
1.
Badly oiled.
2.
After a long use, the cogwheel
and bearings are damaged.
3.
Badly installed or dent.
1.
Oil/Grease the machine.
2.
Change the cogwheel or the
bearings.
3.
Check assembly parts or repair
joints.
The rope winch has too
much voltage.
1.
Earthed error or is not
possible.
2.
The internal connectors are
touching the housing.
1.
Checked earthed wires and
properly connect them.
2.
Check all internal connections.
End-switch is not
functioning.
1.
End-switch is defect.
2.
End-switch is blocked.
1.
Check or change the switch.
2.
Check, repair or change the
end switch.