9. Senior setting 

During power off, press and hold P for 3 sec. into Serior option setting. It includes temperature correction, 

Weekend setting, IP High address    and Low address of 485 communication. Then press P changeover into the 

relative item. At last, confirm it and turn on automatically. 

Code Option 

    or   

 

Temperature compensation in internal sensor 

-9 to +9

2 Path 

selection 

0-3 

485 Communication IP high address (optional) 01--FF 

485 Communication IP low address (optional) 

01--99 

 

10.  Warranty 

We offer the warranty of 12 months, from the sales day. If it is not the quality problems, or beyond the warranty 

period, we will charge for the after-sale service. 