Mode
Description
Values
“20”
flashing
Green Channel Intensity.
Sets the maximum intensity of
the green channel back light. This will be dimmed according
to the display dimming.
If you are in cycle mode, this
setting will be skipped.
Default: 15
Max: 15
Min: 0
“21”
flashing
Blue Channel Intensity.
Sets the maximum intensity of
the blue channel back light. This will be dimmed according
to the display dimming.
If you are in cycle mode, this
setting will be skipped.
Default: 15
Max: 15
Min: 0
“22”
flashing
Cycle Speed.
If you are in cycle mode, this controls the
speed at which the colors cycle. The higher the number, the
slower the colors will change.
If you are not in cycle
mode, this setting will be skipped.
Default: 10
Max: 64
Min: 4
HV Generation Settings (See “HV Settings” note)
“23”
flashing
HV Target Voltage Higher.
Each press sets the HV target
voltage higher by 5V.
Default: 180
Max: 200
Min: 150
“24”
flashing
HV Target Voltage Lower.
Each press sets the HV target
voltage lower by 5V.
“25”
flashing
PWM On Time Longer.
This setting controls how long the
PWM On pulse is. Normally you should not have to change
this, but you can try changing this is the HV generation is
noisy or you have unusual tubes.
Default: 150
Max: 50
Min: 500
“26”
flashing
PWM On Time Shorter.
This setting controls how long the
PWM On pulse is. Normally you should not have to change
this, but you can try changing this is the HV generation is
noisy or you have unusual tubes.
“27”
flashing
Increase Minimum dim.
This setting allows you to
increase the minimum brightness you want to have when
the clock is fully dimmed.
Default: 100
Max: 500
Min: 100
“28”
flashing
Decrease Minimum dim.
This setting allows you to
decrease the minimum brightness you want to have when
the clock is fully dimmed.
“29”
flashing
Increase Anti-ghosting.
This setting reduces “ghosting”
(the number on the right shows faintly on the digit on the
left). This is due to transients when switching.
Default: 0
Max: 50
Min: 0
“30”
flashing
Decrease Anti-ghosting.
This setting reduces “ghosting”
(the number on the right shows faintly on the digit on the
left). This is due to transients when switching.
Information Settings
“31”
flashing
Current case temperature.
Show the current temperature
inside the case (used as part of the temperature
compensation for the clock crystal). Note: This will show 0 if
the RTC is not installed.
“32”
flashing
Clock version.
Show the clock software version.
Digit Test.
Will roll through all digits on all locations to
check that the display is healthy.
Note “HV Settings”:
Before leaving the clock for long periods with a new “HV Generation”
setting, check that neither the MOSFET nor the voltage regulator is running too hot. If either of
these components gets too hot, either adjust the high voltage settings or add a heat sink.