5. Wiring
Fixed wiring installation should be carried out by a qualified person. Power requirements are - 220 -240 Volt AC 50 Hz (2.2kW).
Connect fixed wiring to the terminals marked L, N and earth. The dryer is a Class I appliance and requires a connection to
electrical earth (ground). Suitable fixed wiring conductors size - 1.0 to 2.5mm
2.
6. Refitting the cover
When the wiring connection is completed, move the cover into position, reconnect the switch wire loom and the green/
yellow earth grounding wire, then latch the top first and swing the bottom into place.
Replace the two cover fixing screws. The dryer is now ready for use.
7. Testing and Operation
Turn power on. The dryer will commence immediately hands are placed under the dryer.
Regular Operation
–
The dryer blower will run while hands are placed under the dryer and will stop when hands
are removed.
8. Dry Your Hands Fast
Shake excess water from hands to speed drying. Place hands beneath the air outlet. Rub and rotate hands in
the hot air stream and continue drying until there is no moisture left on hands.
9. Maintenance of your dryer
Clean the exterior cover enclosure using non-abrasive detergents and a soft cotton cloth.
Check the carbon brushes every three years.
V1 061113
198mm
27mm
188
134
Fixed wiring & supply cord entry
All enter from the rear
Flexible cord exit -behind base
Screw dryer to wall here
Screw dryer to wall here
256
Diagram 1
Terminals Marked L N and E
NEW ZEALAND
ARDRICH LIMITED
P + 64 9 570 2861
F + 64 9 570 2864
E [email protected]
AUSTRALIA
ARDRICH HYGIENE PTY LIMITED
P 1 800 058 655
E [email protected]
SOUTH AFRCA
SERVEST HYGIENE
P + 27 11 608 1888
E [email protected]
Switch Wire Loom
Note 1
Note 2
Diagram 2
Note 1
Grounding/earth bonding wires must be
connected to maintain the dryer in a safe
operating condition.
Note 2
If the switch wire loom is not connected, the
dryer will not function.
A260M/SP ARDRICH