Arctiko LTFE 110 Скачать руководство пользователя страница 3

Low Temperature Freezer

In order to get the maximum advantage from your freezer it is important that it is placed in the correct 

position. This manual should therefore be read carefully. Keep the manual in a place where it can always be 

found for reference. Even with careful attention to the freezer, a mishap may occur, with the consequence 

that the contents of the cabinet could be lost, therefore product insurance is recommended.

Placing the freezer

The freezer should not be placed where it might be splashed with 

water, in extreme high humidity or in direct sunlight. Any of these 

factors may lead to a reduction in performance and shorten the 

life span of the components. The freezer should be placed on a 

horizontal level, and should not be placed close to a heating 

appliance or heating tubes.
Allow a minimum of 50mm (2”) clearance on the side and the 

back. The side with the ventilation grill should have a clearance 

of at least 100 mm (4”) in order to allow the heat from the 

compressor motor to dissipate.

Electrical supply

The electrical supply should always be in accordance with the rating plate on the back of the freezer.
The supply must always be in accordance with the law and regulations regarding electrical safety, if any 

doubts contact your supplier.

Starting Up

In case the compressor does not start when the freezer has been plugged in, the electrical supply may not 

be in order. Check if there is an electricity supply to the plug or if the fuse is blown.

Temperature adjustment

The thermostat controls the temperature inside the cabinet. The control is placed in the compressor 

compartment. The higher the number on the dial the lower the temperature. A to low temperature inside the 

cabinet will increase the power consumption. Please check that the temperature is not too low, it must be at 

an adequate level. When the freezer is loaded with products, please make sure that they have a 

temperature of at least -20°C. 
As the appliance is not suitable for freezing products, but meant as a storage unit for pre frozen products. If 

products warmer than -15°C are placed in the freezer, there are a risk of damaging products already in the 

freezer. The products should never be placed above the load line marking inside the cabinet.

Before commissioning

Before commissioning the interior of the freezer should be cleaned with tepid water and dried of with a clean 

cloth. Never use soda or an abrasive cleaning agent as they may damage the inner liner.

3

 

Содержание LTFE 110

Страница 1: ...OPERATING INSTRUCTIONS LTFE 110 210 310 410 510...

Страница 2: ...pply Starting Up Temperature adjustment Before commissioning Operating the freezer Defrosting Cleaning Storage Control panel Trouble shooting Disposal Service Wiring diagram Standard Setting of EVCO C...

Страница 3: ...The supply must always be in accordance with the law and regulations regarding electrical safety if any doubts contact your supplier Starting Up In case the compressor does not start when the freezer...

Страница 4: ...er Never use a sharp metal object which might will cause damage to the inner liner The defrosting frequency is determined mainly by two factors the usage pattern number of lid openings and the relativ...

Страница 5: ...ET key again or wait 60 seconds for the controller to return to normal display of the probe temperature Setting the controllers offset value The freezer is designed for long time and safe storage of s...

Страница 6: ...ently been filled with larger amounts of warm items Is the compressor compartment clean The cupper coil inside the compressor compartment should be free from dust and grease Note Before removing the g...

Страница 7: ...re detailed information about programming the EVCO controllers please consult the attached manuals Standard Setting of EVCO Controller g n i t t e S l e b a L n o i t p i r c s e D C 5 4 P S S T N I O...

Страница 8: ...nt do not use the instrument as safety device for repairs and information on the instrument please contact Evco sales network 19 USER INTERFACE 19 1Turning on off the instrument To turn on the instrum...

Страница 9: ...ANING Loc the keyboard and or the working setpoint are locked parameter r3 also look at paragraph 2 5 22 ALARMS CODE MEANING ALARM First temperature alarm LOW Remedies AL1 check the room temperature l...

Страница 10: ...Wiring diagram for LTFE 110 210 310 Power supply Alarm...

Страница 11: ...Wiring diagram for LTFE 410 510 Power supply Alarm...

Страница 12: ...50 80 003 0 GB WWW ARCTIKO COM LAMMEFJORDSVEJ 5 DK 6715 ESBJERG N DENMARK TEL 45 70 20 03 28 FAX 45 70 20 03 29 INFO ARCTIKO COM WWW ARCTIKO COM...

Отзывы: