Install the unit on strong and leveled surfaces 

-unit may make unpleasant noises if surface is uneven 
-unit may malfunction if surface is uneven 

 Install the unit in an indoor, well-ventilated area 

-unit performs more efficiently in a well-ventilated area 
-for best performance, please maintain clearance of 30 mm on the back of the unit 
-outdoor use may cause decreased efficiency and damage to the unit 

 Avoid installation in a high humidity and/or dusty area 

-humidity could cause unit to rust and decrease efficiency of the unit 
-dust collected on condenser coil will cause unit to malfunction. Clean the condenser at least 

once a month with a brush or clean cloth 

-malfunction due to dirty condenser will void warranty 

 Select a location away from heat and moisture-generating equipment 

-high ambient temperatures will cause the compressor to overwork, leading to higher energy 

bills and gradual breakdown of the unit 

-malfunction due to high ambient temperature will void warranty 

 

 

ELECTRICAL 

Please ensure that the required voltage of the compressor is being always supplied. Low or 
high voltage can detrimentally affect the refrigeration unit. 
All units should be plugged into a grounded and properly sized electrical outlet with 
appropriate overcurrent protection. Please refer to the electrical requirements on the 
nameplate of the unit. Please make sure that your unit has its own dedicated outlet. Do not use 
an extension cord. 

 

TEMPERATURE CONTROLS 

The temperature controls are factory-set to maintain an average temperature of 0 C in 
refrigerators. To maintain a different temperature, simply adjust the thermostat is located at 

All electrical work must be carried out by suitably qualified

 persons 

 

Содержание HEF546

Страница 1: ...stallation Operation Maintenance Manual Upright Refrigerator Freezer HEF546 HEF547 Upright Bottle Coolers HC gas R600 R290 used For warranty Tel 03701 647647 Email address service lockhartcatering co...

Страница 2: ...r electric shock Do not disassemble repair or alter the appliance It may cause fire or abnormal operations Any repair work should be carried by a qualified service agent Do not use store electrical ap...

Страница 3: ...t and moisture generating equipment high ambient temperatures will cause the compressor to overwork leading to higher energy bills and gradual breakdown of the unit malfunction due to high ambient tem...

Страница 4: ...re DEFROST SYSTEMS Refrigerator coils are kept below the freezing point 0 C During compressor down time the evaporator fan continues to circulate air through the evaporator coil This air circulation r...

Страница 5: ...g the unit PROPER GROUNDING REQUIRED To minimize shock and fire hazards make sure that the unit is properly grounded PROHIBITION Do not attempt to remove or repair any component unless instructed by f...

Страница 6: ...the fan motor to prevent moisture damage CLEANING THE INTERIOR OF UNIT When cleaning the cabinet interior use a solvent of warm water and mild soap Do not use steel wool caustic soap abrasive cleaner...

Страница 7: ...Ensure doors are closed when not in use Avoid opening doors for long periods of time Ensure gaskets are snapped in completely Remove gasket and wash with soap and water Check condition of gasket and r...

Страница 8: ...ecialist companies who remove or recycle all glasses metal and plastic components Consult your local waste collection authority regarding disposal of your appliance Local authorities are not obliged t...

Страница 9: ...specification set by international independent and federal authorities Products have been approved to carry the following symbol...

Отзывы: