Arctica HEC906 Скачать руководство пользователя страница 5

 

To manually defrost the appliance:

 

1.

 

Press and hold the DEFROST Button for 5 seconds.

 

2.

 

The defrost cycle will start immediately and the Defrost LED 

illuminates. The defrost will last a maximum of 30minutes.

 

Note: Starting a manual defrost also resets the automatic defrost 

timer. The next automatic defrost will start six hours after the 

manual defrost has finished.

 

3.

 

Waste water is collected in the waste water tray.

 

 

 

Cleaning, Care& Maintenance

 

 Switch off and disconnect from the power supply before cleaning.

 

 Clean the interior of the appliance as often as possible.

 

  Do  not  use  abrasive  cleaning  agents.  These  can  leave  harmful 

residues.

 

Clean the door seal with water only.

 

Always wipe dry after cleaning.

 

 Do not allow water used in cleaning to run through the drain hole 

into the evaporation pan.

 

 Take care when cleaning the rear of the appliance. Sharp edges can 

cut.

 

An agent or qualified technician must carry out repairs if required.

 

 

Cleaning the Condenser

 

Periodically cleaning the condenser can extend the life of the appliance.

 

We  recommend  that  our  agent  or  qualified  technician  clean  the 

condenser.

 

 

 

 

 

Troubleshooting

 

If your appliance develops a fault, please check the following table before making a call to your retailer.

 

 

Fault

 

 

Probable Cause

 

 

Action

 

 

 

The  appliance  is  not 

working

 

The unit is not switched on

 

Check the unit is plugged in correctly and switched on

 

Plug and lead are damaged

 

Call your agent or qualified Technician 

 

Fuse in the plug has blown

 

Replace the fuse

 

Power supply

 

Check power supply

 

Internal wiring fault

 

Call your agent or qualified Technician

 

The  appliance  turns  on, 

but  the  temperature  is 

too high/low

 

 

Too much ice on the evaporator

 

Defrost the appliance

 

Condenser blocked with dust

 

Call your agent or qualified Technician

 

Doors are not shut properly

 

Check doors are shut and seals are not damaged

 

Appliance is located near a heat source or air flow  Move the refrigerator to a more suitable location

 

Содержание HEC906

Страница 1: ...ezer HEC910 HEC912 356 Litre White Refrigerator Freezer HEC911 HEC913 356 Litre Stainless Steel Refrigerator Freezer HED105 HED107 580 Litre White Refrigerator Freezer HED106 HED108 580 Litre Stainless Steel Refrigerator Freezer HEF540 HEF541 HEF542 Glass Door Refrigerators For service during warranty period ...

Страница 2: ...stand or support yourselves on the base drawers or doors DO NOT allow oil or fat to come into contact with the plastic components or door seal Clean immediately if contact occurs DO NOT place more than 30 kg load on each shelf WARNING Keep ventilation openings in the appliance enclosure or In the built in structure clear of obstruction Do not use mechanical devices or other means to accelerate the...

Страница 3: ...S SF60V S 6 1 Door Key Instruction manual Shelf spacer and hook Waste water tray We pride ourselves on quality and service ensuring that at the time of packaging the contents are supplied fully functional and free of damage Should you find any damage as a result of transit please contact your dealer immediately Installation Note If the appliance has not been stored or move in an upright position l...

Страница 4: ...lves Note This is vital for ensuring correct drainage of condensation Operation Storing Food To get the best results from your appliance follow these instructions Only store foodstuffs in the appliance when it has reached the correct operating temperature Do not place uncovered hot food or liquid inside the appliance Wrap or cover food where possible Do not obstruct the fans inside the appliance A...

Страница 5: ...An agent or qualified technician must carry out repairs if required Cleaning the Condenser Periodically cleaning the condenser can extend the life of the appliance We recommend that our agent or qualified technician clean the condenser Troubleshooting If your appliance develops a fault please check the following table before making a call to your retailer Fault Probable Cause Action The appliance ...

Страница 6: ...not properly leveled Adjust the screw feet to level the appliance if applicable The discharge outlet is blocked Clear the discharge ourlet Movement of water to the drain is obstructed Clear the floor of the appliance if applicable The water container is damaged Call your agent or qualified Technician The drip tray is overflowing Empty the drip tray if applicable The appliance is unusually loud Loo...

Страница 7: ... 595 635 1840 72 R600a 128g HEC912 SF40V 220 240VAC 50Hz 2 6 18 22 206 595 653 1840 85 R290 120g HEC913 SF40VS HED105 SR60 220 240VAC 50Hz 2 0 8 376 775 723 1840 81 R600a 145g HED106 SR60S HEF542 SR60VG 220 240VAC 50Hz 2 0 8 350 775 705 1840 85 R600a 145g HED107 SF60V 220 240VAC 50Hz 2 8 18 22 321 775 723 1840 101 R290 110g HED108 SF60VS IN CASE THE SUPPLY CABLE IS DAMAGED THE MANUFACTURER OR THE ...

Страница 8: ...ppliance Local authorities are not obliged to dispose of commercial refrigeration equipment but may be able to offer advice on how to dispose of the equipment locally Compliance Parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international independent and federal authorities Products have been approved to carry the following symbol...

Страница 9: ......

Отзывы: