background image

1)

Power On and Off 

-

 When the unit is plugged in, press the 

POWER       

button to turn on the unit.

 

Press the 

POWER 

button once more to turn the unit off. When in 

Cool

 mode, Auto mode,

 

and Sleep 

mode, the selected temperature will appear on the remote control LCD display. When the

 

unit is in Fan 

mode or D

ry

 mode, no temperature will be displayed. This shows that tempera-ture selection is not 

available when the unit is in Fan mode and D

ry

 mode.

2)

Mode Selection 

-

 Press the 

MODE

 Button repeatedly to cycle between the different modes: Auto,

 

Sleep, 

Cool

, D

ry

, and Fan

-

Only mode. The mode icon on LCD display will light up

 

showing which 

mode is selected.

3)

Fan Speed 

-

 Press the 

FAN HIGH, FAN MED, or FAN LOW 

button to choose desired fan speed.

 

When the unit is in D

ry

 mode, the fan speed cannot be changed. When Turbo Cool is activat-ed, fan 

speed is automatically set on high and is not adjustable in this mode.

4)

Temperature Setting 

-

 When the unit is in 

Cool 

mode, you can select your desired temper-ature. 

Press the ▲ or ▼ to select your desired temperature setting. The temperature on the LCD dis-play on 
the remote control will increase or decrease accordingly. Pressing the 

°C 

/

°F 

button will switch

 

the 

temperature select between °C and °F.

5)

SLEEP MODE  

-

 When in 

Cool

 mode, press the 

SLEEP 

Button on the remote control, Sleep

 

mode 

icon will show on the remote control LCD display. When in 

SLEEP 

mode, the fan will run on low

 

to 

keep fan noise at a minimum. The temperature setting will gradually increase to 2°F above the origi-nal 
set temperature each of first 2 hours. The unit will keep operating the same temperature until the

 

sleep 

mode is turned off.

6)

TIMER 

-

Auto

-

On: 

Press the 

TIMER 

button when the unit is off to set up the Auto

-

on timer. The hour indicator

 

on the LCD display will turn on. Press the 

TIMER

 buttons to set timer within 1

-

24 hours.

Auto

-

Off: 

Press the 

TIMER 

button when the unit is On to set up the Auto

-

off timer. The hour indicator

 

on the LCD display will turn on, Press the 

TIMER

 buttons to set timer within 1

-

24 hours. To cancel the

 

timer, press 

TIMER 

button until the timer mode is turned off.

7)

TURBO COOL 

-

 Press the 

Turbo Cool 

button

 

to activate Turbo Cool mode. The unit will cool at   61°F 

on fan high for 10 minutes and then return to the original settings. Fan speed is not adjustable in this

 

mode. 

NOTE: 

If Fan mode activates less than 3 minutes and switches to Turbo Cool, it will be a compressor pro-

tection shut down, compressor will turn on again until the 3 minutes is topped off.

 

8)

MY TEMP MODE 

-

 Press this button to change the thermostat sensor from the air conditioner to the

remote control location. The air conditioner will cool the area at the location and set temperature of the
remote control.

9)

CHILD LOCK

– Press this button to lock/unlock the remote control buttons.

8

REMOTE CONTROL

Содержание AP6018

Страница 1: ...Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL PORTABLE AIR CONDITIONER FOR MODEL AP6018 ...

Страница 2: ...fore use If the power cord is damaged it must be replaced by WKH PDQXIDFWXUHU RU D TXDOLILHG VHUYLFH WHFKQLFLDQ 11 When cleaning the unit always turn the unit off and unplug the power cord 12 Do not mix old and new batteries in the remote control N Portable Air conditioners are pieces of high value In order to ensure your lawful rights and interests please have the professional technicians to do t...

Страница 3: ...r 7 Hot Air Discharge Opening 8 Air Intake Grille 9 Condensation Drain Hole 10 Exhaust Hose 11 Exhaust Hose Connector 12 Window Kit Adapter 13 Window Kit Panels 14 Wing Nuts 15 Optional Drain Tube 16 Drain Tube Stopper 17 Remote Control 18 Batteries 19 Optional Window Security Pack 20 Type B Screw 1 PRODUCT DIAGRAM ...

Страница 4: ...unit in Air Conditioning or Dehumidification Mode When the unit is operating in Fan Mode no outdoor air exchange takes place The window kit and exhaust hose do not need to be installed when the unit is used as a fan The supplied window kit can be installed in sliding windows and sliding glass doors up to 7 ft long approximate length When installed be sure to keep the exhaust hose as short and stra...

Страница 5: ... 3 WINDOW KIT ASSEMBLY ...

Страница 6: ...the opening If necessary mark the kit and cut one end down to properly fit the opening 2 Twist the Exhaust Hose Connector over the discharge opening on the back of the unit and extend the Exhaust Hose Keep the exhaust hose as short and straight as possible 3 Attach the Window Kit Adapter to the Exhaust Hose Close the window or door tightly Then attach the Window Kit Adapter to the Window Kit panel...

Страница 7: ...on Your Window Kit also includes an optional security bracket that can be installed to prevent the window from being opened from the outside while a Window Kit is installed Single and Double Hung Windows Sliding Windows 5 SECURITY BRACKET ...

Страница 8: ...r The temperature indicator display shows temperature in Fahrenheit While the unit is plugged in but not powered on press and hold the and buttons for 3 seconds to switch between Celsius and Fahrenheit 4 Fan Speed Press FAN SPEED button to choose fan speed in High Medium or Low 5 Timer Press TIMER button to set the unit automatically turn ON or OFF Use the and buttons to program the hour increment...

Страница 9: ...LCD DISPLAY POWER BUTTON TIMER TEMP DECREASE TIMER TEMP INCREASE REMOTE LOCK BUTTON SLEEP BUTTON TIMER BUTTON TURBO COOL BUTTON C F SWITCH BUTTON MODE BUTTON FAN SPEED MY TEMP BUTTON 7 REMOTE CONTROL ...

Страница 10: ...ep mode icon will show on the remote control LCD display When in SLEEP mode the fan will run on low to keep fan noise at a minimum The temperature setting will gradually increase to 2 F above the origi nal set temperature each of first 2 hours The unit will keep operating the same temperature until the sleep mode is turned off 6 TIMER Auto On Press the TIMER button when the unit is off to set up t...

Страница 11: ...m will also improve the cool ing efficiency NOTE When the unit is running on air conditioning mode the exhaust hose is required and must be vented outside using the supplied window kit Dry Mode 1 Install the exhaust hose and window kit properly see pages 3 4 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER Button 4 Press the MODE button until the dry mode in...

Страница 12: ...icator Fan Mode 1 Plug the Power Cord into an electrical outlet 2 Turn on the unit by pressing the POWER button on the control panel 3 Press the MODE button until the FAN mode indicator lights up on the control panel display 4 Select the fan speed by pressing the FAN SPEED button NOTE It is not necessary for the exhaust hose and window kit to be installed to operate the unit in fan mode Auto Mode ...

Страница 13: ...e water will drain out automati cally 4 When the drain pan is full install the drain plug back onto the condensation drain hole to stop the water flow 5 Empty the drain pan 6 Repeat steps 2 5 until all the water is emptied NOTE Once the condensate tank has been emptied firmly press the drain plug back onto the condensa tion drain hole Fig 15 1 It is not advised to use continuous drainage when the ...

Страница 14: ...r is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the unit 1 Empty any excess water by unplugging the...

Страница 15: ... there is an unpleasant smell in the room Air filter is dirty Remove air filters clean and re install Air conditioner does not oper ate after restarting the unit The internal compressor safety de vice prevents the unit from being restarted until three minutes have elapsed since it was last turned off Wait for compressor to turn on The control panel display shows Error codes The unit has a self dia...

Страница 16: ...buted by Perfect Aire LLC 5401 Dansher Rd Countryside IL 60525 844 472 2473 www arcticwindac com Specification and performance data is subject to change without notice Printed in China AW User_AP6018 12152017 ...

Отзывы: