TROUBLESHOOTING TIPS

Before calling for service, review the chart below first yourself.

Problem

What to check

Unit does not start

Make sure the dehumidifier s plug is pushed completely into the
outlet.
Check the house fuse/circuit breaker box.
Dehumidifier has reached its preset level or bucket is full.
Water bucket is not in the proper position.

Dehumidifier does not
dry the air as it should

Did not allow enough time to remove the moisture.
Make sure there are no curtains, blinds or furniture blocking the
front or back of the dehumidifier.
The humidity control may not be set low enough.
Check that all doors, windows and other openings are securely
closed.

O

O

Room temperature is too low, below 5 C(41 F).
There is a kerosene heater or something giving off water vapor
in the room.

,

The unit makes a loud
noise when operating

The air filter is clogged.
The unit is tilted instead of upright as it should be.
The floor surface is not level.

Frost appears on the 
coils

This is normal. The dehumidifier has Auto defrost feature.

Water on floor

Hose to connector or hose connection may be loose.
Intend to use the bucket to collect water, but the back 
drain plug is removed.

ES, AS,P2 and EC 
appear in the display

These are error codes and protection code. See the 

CONTROL 

PADS ON THE DEHUMIDIFIER

 section. 

10

10

11

11

Содержание AKDH-30Pt4

Страница 1: ...manufacturer for details CD018IU K K5 BJ The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details CD01...

Страница 2: ...st free of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wild disposal of waste in forests and landscapes endangers your health when hazardous...

Страница 3: ...the unit and cause electric shock Do not take the water buc ket out during operation SAFETY PRECAUTIONS Do not cover the intake or exhaust openings with cloths or towels A lack of air flow can lead to...

Страница 4: ...sting the timer setting to 0 0 will cancel the Auto Start Stop function When LED display window displays the code of P2 the Auto Start Stop function will also be cancelled When the unit is off first p...

Страница 5: ...wn Casters At four points on the bottom of unit Casters can move freely Do not force casters to move over carpet nor move the unit with water in the bucket The unit may tip over and spill water Adehum...

Страница 6: ...ig 12 4 When not using the unit for long time periods CARE AND MAINTENANCE Care and cleaning of the dehumidifier Turn the dehumidifier off and remove the plug from the wall outlet before cleaning 1 Cl...

Страница 7: ...ty control may not be set low enough Check that all doors windows and other openings are securely closed O O Room temperature is too low below 5 C 41 F There is a kerosene heater or something giving o...

Отзывы: