48
B. When using a constant-current battery charger, use the
following Battery Charging Chart.
NOTE: If the battery voltage is 11.5 DC Volts or less,
some chargers may “cut off” and fail to charge. If this
occurs, connect a fully charged booster battery in parallel
(positive to positive and negative to negative) for a short
period of time with the charger connected. After 10-15 min-
utes, disconnect the booster battery leaving the charger
connected and the charger should continue to charge. If
the charger “cuts off,” replace the battery.
6. After charging the battery for the specified time, remove the
battery charger and allow the battery to sit for 1-2 hours.
7. Connect the multimeter and test the battery voltage. The
meter should read at least 12.5 DC Volts. If the voltage is as
specified, the battery is ready for service.
NOTE: If voltage in step 7 is below specifications, charge
the battery an additional 1-5 hours; then retest.
8. Place the battery in the battery compartment; then coat the
battery posts and cable ends with a light coat of multi-pur-
pose grease.
9. Connect the battery cables (positive cable first); then install
the battery hold-down.
NOTE: Arctic Cat highly recommends all ATV batteries
be connected to a maintenance charger during storage or
any extended period of non-use. The charger MUST have
an automatic float, storage-safe, or pulse maintenance
mode to avoid battery damage due to long-term overcharg-
ing. To connect the maintenance charger, use any of the
following procedures.
A. Remove the battery cover; then connect the charger leads
(positive cable first) directly to the battery.
B. Locate the rear accessory connector and connect the char-
ger leads (positive cable first) directly to the connector.
CAUTION
Never exceed the standard charging rate.
! WARNING
An overheated battery could explode causing severe injury
or death. Always monitor charging times and charge rates
carefully. Stop charging if the battery becomes very warm
to the touch. Allow it to cool before resuming charging.
Battery Charging Chart (Constant-Current Charger)
Battery Voltage
(DC)
Charge
State
Charge Time Required
(at 1.5-2.0 Amps)
12.5 or more
100%
None
12.2-12.4
75%-99%
3-6 hours
12.0-12.2
50%-74%
5-11 hours
11.0-11.9
25%-49%
13 hours (minimum)
11.5 or less
0-24%
20 hours (minimum)
CAUTION
Before installing the battery, make sure the ignition switch
is in the OFF position.
CAUTION
Connecting cables in reverse (positive to negative and neg-
ative to positive) can cause serious damage to the electri-
cal system.