Appliance Placement

Leave a three (3) inch space on all sides and the back
of the cabinet for adequate air circulation. Choose a
place that is near a grounded electrical outlet. For the
most efficient operation, the appliance should be
located where surrounding temperatures will not
exceed 110°F (43°C). Appliance should not be
operated in ambient below 32°F (0°C). Additional
compressor heaters are not recommended.

Insulation

The insulated space of this cabinet is sealed to
maintain peak efficiency. Holes drilled in the cabinet
may destroy that seal and damage electrical wiring
located in the insulated space.

DAMAGED ELECTRICAL WIRING OR WET
INSULATION CAUSED BY DRILLING WILL VOID
THE WARRANTY.

Appliance Start-Up

Once the appliance has been located in its permanent
location and the proper power and grounding has
been provided, the following items must be checked
or completed:

Cool Down Period

For safe food storage, allow 24 hours for the
appliance to cool down completely before loading
with food. The appliance will run continuously for the
first several hours. Do not place any food in the
appliance until after the first 24 hours of operation.

Thermostat Settings

The appliance is shipped from the factory with the
thermostat set at about the mid-point of the
operating range. Adjustments colder or warmer can
be made after the appliance has been running for at
least 8 hours. Allow at least 8 hours for temperature
stabilization before re-adjusting the thermostat.

Defrost Setting

The appliance is designed to defrost automatically
every 12 hours. To set the time of defrost, wait until
the desired time to defrost. With the notch on the
timer knob aligned with the line on the bracket
(Figure A), turn the defrost timer knob clockwise
slowly. The timer will click several times, then once
loudly, at which point the defrost cycle begins. The
timer knob will advance through the defrost cycle,
then click loudly at the end of the cycle (Figure B).
The appliance will defrost automatically every 12
hours after the first defrost cycle.

For example, to set the appliance to defrost at 10:00
a.m., turn the timer knob clockwise at 10:00 a.m.
until the timer clicks loudly. The appliance will defrost
daily at 10:00 a.m. and again 12 hours later at 10:00
p.m.  

Note:

 The products' internal temperature will rise

during the defrost cycle every 12 hours.

Defrost Timer

Back of Unit

Shelves

The appliance is provided with 4 shelves.  One goes on
the floor of the cabinet and the other 3 are placed in
the metal side supports wherever they are needed. The
shallow shelf goes in the upper position.

Features

• Heavy duty epoxy powder coated adjustable shelving
• Heavy duty commercial door lock
• 3 inches of door insulation
• NSF certified top mounted evaporator
• 2-1/2" urethane foam cabinet insulation
• Reversible door
• Spring loaded door closer
• Heavy duty swivel casters
• Stainless steel door edge guard and handle
• 40 watt shatterproof bulb
• Removable stainless steel drain cover
• Adjustable temperature control
• NSF certified interior
• Stainless steel evaporator housing
• Stainless steel toe plate
• Heavy duty commercially rated electrical harness
• Heavy duty removable stainless steel shelf supports

Figure A

Position of knob

before turning clockwise

to start defrost cycle.

Figure B

Position of knob

at end of defrost cycle.

Содержание F22CW13

Страница 1: ...l Information 2 Installation and Setup 3 Appliance Start Up 4 Features 4 Routine Maintenance 5 Reversing Door 6 Energy Conservation Measures 7 Avoid Service Checklist 8 Wiring Diagram 10 If You Need S...

Страница 2: ...use these items to play Cartons covered with rugs bedspreads plastic sheets or stretch wrap may become airtight chambers and can quickly cause suffocation Remove all staples from the carton Staples c...

Страница 3: ...uts See following illustration Electrical Information These guidelines must be followed to ensure that safety mechanisms in the design of this appliance will operate properly Refer to the serial plate...

Страница 4: ...12 hours To set the time of defrost wait until the desired time to defrost With the notch on the timer knob aligned with the line on the bracket Figure A turn the defrost timer knob clockwise slowly T...

Страница 5: ...s a special bulb with a shatterproof coating Use an NSF certified bulb of the same type and wattage can be ordered from your Arctic Air Service Center at 1 800 490 9574 P N 2163600900 Routine Maintena...

Страница 6: ...Slightly loosen the two hex spacers that the toe plate screws were screwed into 3 Holding door securely closed remove three 3 hex head screws from the top hinge and flat spacer 4 Lift appliance door o...

Страница 7: ...e cabinet Energy Conservation Measures The appliance is designed for efficiency with heavy foam insulation However there are things that the user can do to maintain the appliance in operating conditio...

Страница 8: ...cause appliance to run longer in order to maintain desired temperature Temperature control is set too cold Turn the control to a warmer setting Allow several hours for the temperature to stabilize Tem...

Страница 9: ...r is kept open too long or is opened too frequently Open the door less often Door is slightly open causing the cold air from inside the appliance to meet warm moist air from outside See Occurrence sec...

Страница 10: ......

Страница 11: ...iveryslip orsomeotherappropriatepaymentrecord Thedateonthebillestablishes the warranty period should service be required If service is performed it is in your best interest to obtain and keep all rece...

Страница 12: ...ir s option the warranty part s In addition ARCTIC AIR warrants that the compressor shall be free from defects for a total period of five 5 years This warranty will be effective with the earliest of e...

Отзывы: