Installation, Operation & Maintenance Manual
7
UNDER-COUNTER REFRIGERATORS AND FREEZERS
INSTALLATION
Location
All.units.are.intended.for.indoor.use.only..A.fully.loaded.
unit.can.weigh.as.much.as.1500.pounds...Choose.a.loca-
tion with a level floor strong enough to support the total
weight of a fully loaded unit. Reinforce the floor if neces-
sary..
For the most efficient refrigeration, provide good air cir-
culation.around.the.unit..
Inside cabinet
Do.not.pack.the.unit.interiors.so.that.air.circulation.is.im-
peded..The.refrigerated.air.is.discharged.at.the.top.rear.
of the unit. Allow for proper air flow from the top rear to
the bottom of the unit. Obstructions to this air flow can
cause.evaporator.coil.freeze.ups.and.loss.of.temperature.
or overflow of water from the evaporator drain pan. The
shelves.have.a.rear.turn.up.on.them.to.prevent.obstruc-
tions to the rear air flow. However, bags and other items
located. at. the. rear. of. the. cabinet. may. obstruct. the. air.
flow.
Outside cabinet
Be sure that the unit has access to ample air flow. Avoid
hot.corners.and.locations.near.stoves.and.ovens..Do.not.
install.the.unit.closer.than.two.inches.from.a.wall..To.pre-
vent.air.obstruction,.do.not.locate.large.boxes.and/or.tall.
stacks.of.product.that.might.obstruct.the.air.exhaust.or.
the.air.inlet.
CAUTION
If the unit is laid on its side or back for any reason,
allow a minimum of 24 hours in the upright position,
before start-up to allow compressor oil to flow back
to the sump. Failure to meet this requirement can
cause compressor failure, unit damage, and will
void the unit warranties.
Electrical connection
Refer. to. the. amperage. data. provided. in. the. SPECIFI-
CATIONS,.the.serial.tag,.the.local.electrical.code.and/or.
the.National.Electrical.Code..Have.a.licensed.electrician.
confirm that the facility wiring is adequate for the unit and
that.a.protected.circuit.of.the.correct.voltage.and.amper-
age is provided for each unit. Confirm that the unit is
connected.only.to.the.proper.protected.power.source..
DANGER
TURN THE ON/OFF SWITCH TO OFF AND
DISCONNECT THE UNIT FROM THE POWER
SOURCE WHENEVER PERFORMING SERVICE,
MAINTENANCE FUNCTIONS OR CLEANING
THE UNIT.
Leveling
Level.the.cabinet.to.improve.performance,.to.better.align.
the. doors,. to. reduce. uneven. strain. on. the. cabinet. and.
reduce.movement.of.the.contents.on.the.shelves..Use.a.
level.to.level.the.unit.from.front.to.back.and.side.to.side..
Units. supplied. with. legs. have. adjustable. bullet. feet. to.
make.the.leveling.adjustments..If.the.unit.is.supplied.with.
casters,. no. leveling. adjustments. are. available.. Ensure.
the floor is level, where the casters unit is located.
Stabilizing
Casters.are.provided.for.convenience,.ease.of.cleaning.
underneath.and.for.mobility..Install.the.unit.on.a.level.sur-
face,. in. a. stable. condition. and. lock. the. front. wheels. to.
prevent.movement.
Total Restaurant Supply - https://totalsupply1.com - Toll Free 1-800-944-9304 - Local 507-288-9454
2940 Hwy 14 W, Rochester, MN 55901