7.0 Manipulation of the instructions
7.1 Correct operation instructions for machine
startup
⚫
Pull and step handle (1) and pedal (6)
respectively to lower the squeegee and brush
plate to the ground
。
⚫
Observe and confirm or press the "O" button
of the water suction motor switch (10) and
the brush disk motor switch (12) to be in the
"press" state to close
⚫
Turn on the power lock switch clockwise with
the key (09). The indicator light is on(11)
⚫
Press the "I" button of switch (10) and switch
(12) successively to start the machine
normally
⚫
Adjust the amount of water as required (14)
7.2 Warning and operation instructions of full
water in sewage tank
⚫
When the sewage level in the sewage tank
is close to the maximum limit water level,
the buoy (15) will jump up and block the
air outlet (17), so that the vacuum motor
cannot work properly and make different
noises. (The suction trap will drain the
water off the ground
)
⚫
Turn off the suction motor and the brush
motor immediately
⚫
Lift the brush tray and squeegee
⚫
Move the machine to the location of
sewage discharge, remove the sewage
hose (16) from the bracket clamp, and
remove the pipe cover in the opposite
direction to drain the sewage.