background image

 © 2020 Carrier. All rights reserved.

A Carrier Company 

Edition Date: 08/20

Catalog No: 518022001107

Replaces: 

518022001106

PHD4, WPH4: Owner’s Information Manual

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

6

Table 2 – Maintenance Checklist

Monthly maintenance items and outdoor unit rinsing may be performed by the consumer.  All other maintenance items and all service work must be

performed by a qualified service technician.  Read all Warning labels.

Description of Maintenance

Recommended Interval

Consumer specific:

Monthly

Annual

Inspect, clean, or replace air filter if filter is located indoors in return air duct.

X

Clear away debris and vegetation near unit.

X

Dealer specific:

Inspect cabinet and basepan for damage.  Replace panels, gaskets, and other components that are damaged or severely 

rusted.  Make sure precipitation has not  entered indoor section of unit.

X

Inspect electrical disconnect for proper function.  Repair or replace as necessary.

X

Inspect electrical wiring and connections.  Tighten loose connections.  Inspect and perform functional test of equipment as 

needed to ensure proper function.  Repair or replace damaged or overheated components and wiring.

X

Inspect electric heater, if installed.  Check for signs of overheating of elements, controls, and wiring.  Make sure heater 

elements are not broken or electically shorted.

X

Check refrigerant system subcooling and/or superheat  (system dependent).

X

Inspect inside of unit.  Clean if debris is present.

X

Inspect condenser coil.  Clean if dust, dirt, or debris is present.  Rinse unit with fresh water (see Note 2).

X

Inspect condenser motor and fan for damage.  Make sure fan spins freely.

X

Inspect and clean blower assembly (includes blower housing, wheel, and motor).

X

Inspect evaporator coil.  Clean if dust, dirt, or debris is present (see Note 2).

X

Clean condensate pan and drain lines (more frequent maintenance may be required in humid climates).

X

Inspect airflow system (ductwork).  Check for leaks and repair as needed.

X

Notes:

1. The above list may not include all maintenance items.  Inspection intervals may vary depending on climate and operating hours.  Consult your HVAC dealer about a service 

contract for seasonal inspections.

2. Do not use harsh chemicals or high pressure water on coils.  More frequent rinsing is required for units near a sea coast.

Содержание PHD4

Страница 1: ...s 24 60 Single Packaged Heat Pump System with R 410A Refrigerant Technician Name Phone Number Address Company Name Date Installed NOTE TO EQUIPMENT OWNER For your convience please record the model and serial numbers of your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maintenance or ...

Страница 2: ...or unit and for water to drain from the outside of unit Do not be alarmed To start the unit 1 Turn on the electrical power supply to unit 2 Set MODE control to desired mode and select temperature To shut off unit NOTE If the unit is being shut down because of a malfunction call your dealer as soon as possible 1 Set system MODE control to OFF 2 Turn off the electrical power supply to unit Cooling M...

Страница 3: ... an air filter in place before it can be operated These filters should be located in at least one of two places In many applications the installer will provide return air filter grilles mounted on the wall or ceiling of the conditioned structure In the instance of filter grilles the filters can simply be removed from the grille and replaced The other typical application is an accessory filter rack...

Страница 4: ...heck without proper instrumentation If there are any discrepancies in the operating cycle contact your local dealer and request service Refrigerant Circuit The refrigerant circuit is difficult to check for leaks without the proper equipment If inadequate cooling is suspected contact your local dealer for service Unit Panels After performing any maintenance or service on the unit be sure all panels...

Страница 5: ... sure they are open and unobstructed If these checks do not reveal the cause call your servicing dealer If your unit is not operating at all check the following list for easy solutions Check to be sure that your thermostat temperature selector is set below the indoor temperature during the cooling season or above the indoor temperature during heating season Be sure the SYSTEM switch or MODE contro...

Страница 6: ...ctions Inspect and perform functional test of equipment as needed to ensure proper function Repair or replace damaged or overheated components and wiring X Inspect electric heater if installed Check for signs of overheating of elements controls and wiring Make sure heater elements are not broken or electically shorted X Check refrigerant system subcooling and or superheat system dependent X Inspec...