INSTALLATION INSTRUCTIONS

Modular Blower 

(115 Volt)

MB08B1500B, MB12F1900B, MB16J2200B, MB20L2400B

These instructions must be read and understood completely before attempting installation.

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service,

maintenance, or use can cause explosion, fire, electrical

shock, or other conditions which may cause death,

personal injury, or property damage. Consult a qualified

installer, service agency, or your distributor or branch for

information or assistance. The qualified installer or

agency must use factory

authorized kits or accessories

when modifying this product. Refer to the individual

instructions packaged with the kits or accessories when

installing.

Follow all safety codes. Wear safety glasses, protective

clothing, and work gloves. Use quenching cloth for

brazing operations. Have fire extinguisher available.

Read these instructions thoroughly and follow all

warnings or cautions included in literature and  attached

to the unit. Consult local building codes, the current

editions of the  National Electrical Code (NEC) NFPA

70.

In Canada refer to the current editions of the Canadian

Electrical Code CSA C22.1 Recognize safety

information. This is the safety

alert symbol 

!

 

!

 When

you see this symbol on the unit and in instructions or

manuals, be alert to the potential for personal injury.

Understand these signal words; 

DANGER

WARNING

,

and 

CAUTION

. These words are used with the

safety

alert symbol. 

DANGER

 identifies the most

serious hazards which 

will 

result in severe personal

injury or death. 

WARNING

 signifies hazards which

could 

result in personal injury or death. 

CAUTION

 is

used to identify unsafe practices which 

may 

result in

minor personal injury or product and property damage.

NOTE

 is used to highlight suggestions which 

will

 result

in enhanced installation, reliability, or operation.

TABLE OF CONTENTS

General Information/Installation

2

. . . . . . . . . . . . . . . . . . 

Installation

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Horizontal Installation

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . 

Ductwork Connection

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . 

Filter Installation

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Electrical Connection

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . 

Motor Speed and Airflow

5

. . . . . . . . . . . . . . . . . . . . . . . . 

Blower Performance

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Airflow Check

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Wiring Diagram

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Replacement Parts

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

!

WARNING

ELECTRICAL SHOCK HAZARD
Failure to turn off electric power could result in per-

sonal injury or death.
Before installing or servicing system, turn off main

power to the system. There may be more than one

disconnect switch, including accessory heater(s).

Содержание MB08B1500B

Страница 1: ... of the National Electrical Code NEC NFPA 70 In Canada refer to the current editions of the Canadian Electrical Code CSA C22 1 Recognize safety information This is the safety alert symbol When you see this symbol on the unit and in instructions or manuals be alert to the potential for personal injury Understand these signal words DANGER WARNING and CAUTION These words are used with the safety aler...

Страница 2: ...rt space in the front of the unit for service access clearance for return air and supply duct connections space for refrigerant piping connections and condensate drain line connections THESE BLOWERS ARE NOT TO BE USED WITH ELECTRIC HEAT If the unit is located in an area of high humidity nuisance sweating of casing may occur On these installations a wrap of 2 51mm fiberglass insulation with a vapor...

Страница 3: ...ments They must have the drain pan repositioned for right hand airflow Refer to coil installation manual CAUTION PROPERTY DAMAGE HAZARD Failure to follow this caution may result in property damage A field fabricated auxiliary drain pan with a separate drain is REQUIRED for all installations over a finished living space or in any area that may be damaged by overflow from a restricted main drain pan...

Страница 4: ...NT PROTECTION The power supply wiring to the unit MUST be provided with overcurrent protection Governing codes may require this to be fuses ONLY or circuit breakers For blower cabinets MB08 MB12 and MB16 a 15 AMP circuit should be used For MB20 a 20 AMP circuit should be used LINE VOLTAGE CONNECTIONS Line voltage wiring may be brought into the unit through the top right hand corner A hole for a 1 ...

Страница 5: ...pitot tubes or other accurate pressure sensing devices 3 Connect these taps to a level inclined manometer or draft gauge 4 Ensure the coil and filter are clean and all the registers are open 5 Determine the external static pressure with the blower operating 6 Refer to the Air Flow Data tables to find the speed tap that will most closely provide the required air flow for the system 7 Refer to Motor...

Страница 6: ...PPER 1 1 1 1 1176316 11 B6001801 BACK WRAPPER 1 1176312 B6001802 1 1176313 B6001803 1 1176314 B6001804 1 1176315 12 B60020 R H SIDE WRAPPER 1 1 1 1 1176317 Replacement Parts Expanded View B50086B KEY NO PART NUMBER DESCRIPTION MB08B1500B2 MB12F1900B2 MB16J2200B2 MB20L2400B2 OLD PART 13 B6003601 BRACE BOTTOM FRONT 1 1069603 B6003602 1 1069604 B6003603 1 1069605 B6003604 1 1087670 14 B6005601 DECK B...

Отзывы: