Connect the controller DMX input to the DMX output of the first unit.;
•
Connect the DMX output to the DMX input of the following unit. Connect again the output to the input
of the following unit until all the units are connected in chain.
•
When the signal cable has to run longer distance is recommended to insert a DMX termination on the
last unit.
The termination avoids the risk of DMX 512 signals being reflected back along the cable when they
reaches the end of the line: under certain conditions and with certain cable lengths, this could cause
them to cancel the original signals. The termination has to be prepared by soldering a 120Ω 1/4 W resis-
tor on the last element of the DMX chain, between pins 2 and 3.