• Clean the burner assembly and bowl with a wet cloth or cleaning solution to remove carbon build-up,
frequency of the cleaning will depend on usage.
• Inspect the gap between the base of the bowl and the mounting bracket. It should be kept free of dirt and debris
that may restrict ventilation and drainage (see Figure 3).
• Periodically inspect the underside of the burner assembly for any signs of excessive temperatures.
Check that all gas connections are tight.
• The vessel and burner assembly should be covered and protected from extreme weather conditions.
• The burner should not be operated in high wind conditions.
Note: If any problems occur, consult a licensed heating professional or call Architectural Pottery.
Product
Maintenance
6
Figure 3
KEEP SPACE BETWEEN GFRC
VESSEL AND MOUNTING
BRACKET CLEAR OF DEBRIS.
DO NOT SEAL.
CAUTION! Use only approved decorative media to cover the burner assembly.
Architectural Pottery Tumbled Lava Rock and Fire Glass are accepted media. Use
caution when in the immediate area, as pieces may pop or explode when exposed to
heat or moisture.