Architectural Area Lighting PROS Providence Small Скачать руководство пользователя страница 10

INSTALLATION INSTRUCTIONS

CATALOG NUMBER

PART NO.

APPRVD

DATE

DATE

REV.

14249 Artesia Blvd.  P.O. Box 1869

La Mirada, CA  90638-1869

(714)994-2700  fax(714)994-0522

A96486

PROS DIR 

 

WARNING: THIS PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER
REPRODUCTIVE HARM. THOROUGHLY WASH HANDS AFTER INSTALLING, HANDLING, CLEANING OR OTHERWISE TOUCHING THIS PRODUCT. 

 

TRA59U

LATCH

CLOSED

TENON

FIXTURE

(BY OTHERS)

CONNECTORS

DOME

4" O.D. POLE (REF)

TABS

BALLAST

FITTER CAP

(ORIENTATION)

2.

2.

4. SERVICE BALLAST.

LAMP SERVICING:

MOUNTING HARDWARE
FOR POLE BY AAL,

FOR POLE BY OTHERS,
HARDWARE BY OTHERS.

HARDWARE INCLUDED.

OPEN

SHCS S/S

3.

4.

TURN OFF POWER.

1.

TURN POWER OFF.

3.

1.

3/8-16 X 1" LG

(2) P/N A84186

6.

7.

(BY OTHERS)

5/16-18 X 1/4"

(3) P/N 93007472

SET SCREW S/S

1.

2.

3.

5.

4.

CONNECTORS

LAMP (REFERENCE)

FITTER CAP DETAIL

INCOMING EQUIPMENT GROUND SUPPLY.

PLACE WIRING IN POLE AND SECURE ARM TO POLE

ROTATE FITTER CAP CLOCKWISE, UNTIL TABS SNAP

BALLAST SERVICING COMPLETE.

BALLAST INTO FITTER.

SECURELY INTO FITTER.

ROTATE FITTER CAP COUNTER CLOCKWISE, UNTIL

UNPLUG ALL CONNECTORS.

BALLAST SERVICING:

LIFT FITTER CAP WITH BALLAST FROM FITTER AND

FREE FROM FIXTURE. (SEE FITTER CAP DETAIL)

CLOSE DOME AND LATCH SECURELY.
LAMP SERVICING COMPLETE.

PULL LATCH AND RAISE DOME AS SHOWN.
INSTALL LAMP (BY OTHERS). AND

MOUNTING HOLES

PLUG IN CONNECTORS FROM ARM TO FIXTURE AND

TO TENON WITH (3) 5/16-18 x 1/4" SET SCREWS.

SLIP FIXTURE OVER TENON, AND SECURE FIXTURE

INSTALLATION COMPLETE.

LEADS TO ARM LEADS, AS SHOWN. (WHITE TO

NOTE: ASSEMBLY MUST BE GROUNDED TO THE

TURN OFF POWER.

INSTALLATION STEPS:

MAKE WIRE CONNECTIONS FROM INCOMING WIRE

(HARDWARE AS NOTED).

PLUG IN ALL CONNECTORS AND CAREFULLY PLACE

5.

INCOMING WIRE LEADS

COMMON, BLACK TO HOT AND GREEN TO GROUND).

WIRE CONNECTIONS

ARM

3.5

10.00

WIREWAY

(2) 

O

 7/16"

CLEARANCE

2

1

2

1

Содержание PROS Providence Small

Страница 1: ...3 4 5 WARNING Fixtures must be grounded in accordance with local codes or the National Electrical Code Failure to do so may result in serious personal injury MAINTENANCE A regularly scheduled maintena...

Страница 2: ...nplug all connectors remove guts and discard 2 Rotate fitter cap counter clockwise until free from fixture See fitter cap detail unplug all connectors remove guts and discard TURN OFF ALL POWER TO THE...

Страница 3: ...fitter cap with same hardware as shown in the illustration below 3 For wiring diagrams POST TOP MOUNT TRA59U ARM WMA59U ARM UPWARD OPTIONS see page 4 TRA59D ARM WMA59D ARM DOWNWARD OPTIONS see page 5...

Страница 4: ...T TOP MOUNT TRA59U WMA59U UPWARD OPTIONS WMA59U ARM OPTION TRA59U ARM OPTION POST TOP MOUNT OPTION POLE REF BOND TO BOTTOM DOME BOND TO FITTER GROUND TO FITTER BOND TO TOP DOME ITEM 3 5X 93035846 CONN...

Страница 5: ...S 5 CABLE CONDUCTOR YELLOW GREEN BLUE GRAY BLACK BROWN YELLOW GREEN BLUE ORANGE PURPLE BROWN GRAY BLACK BLUE YELLOW BROWN GREEN OSRAM OPTOTRONIC OT50W UNV GRAY RED GRAY WHITE BLACK WHITE GREEN BLACK W...

Страница 6: ...93007472 SET SCREW S S 5 16 18 X 1 4 TURN OFF POWER INSTALLATI ON STEPS CLOSED BY OTHERS CONNECTORS CAREFULLY PLACE FITTER CAP INTO FITTER LAMP SERVICING COMPLETE SNAP SECURELY INTO FITTER ROTATE FIT...

Страница 7: ...OTHERS LIFT FITTER CAP FROM FITTER ROTATE FITTER CAP COUNTER CLOCKWISE UNTIL INSTALLATION COMPLETE 3 8 16 X 1 LG 2 P N A84186 SHCS S S LAMP SERVICING COMPLETE SNAP SECURELY INTO FITTER FREE FROM FIXT...

Страница 8: ......

Страница 9: ...DETAIL PULL LATCH AND LOWER FIXTURE AS SHOWN INSTALL LAMP BY OTHERS AND CLOSE FIXTURE AND LATCH SECURELY LAMP SERVICING COMPLETE DOME DETAIL MOUNTING PATTERN 5 6 3 8 16 X 1 LG 2 P N A84186 LEADS TO A...

Страница 10: ...EFERENCE FITTER CAP DETAIL INCOMING EQUIPMENT GROUND SUPPLY PLACE WIRING IN POLE AND SECURE ARM TO POLE ROTATE FITTER CAP CLOCKWISE UNTIL TABS SNAP BALLAST SERVICING COMPLETE BALLAST INTO FITTER SECUR...

Страница 11: ...EADS INCOMING FRONT OF ARM MOUNTING HARDWARE CONNECTORS BY OTHERS MOUNTING PLATE BALLAST SERVICING COMPLETE INSTALL LAMP BY OTHERS CLOSE FIXTURE AND PULL LATCH AND LOWER FIXTURE AS SHOWN ORIENTATION M...

Страница 12: ...S SILICONE MOUNTING PLATE FITTER CAP DETAIL CLOSE DOME AND LATCH SECURELY LAMP SERVICING COMPLETE RAISE FIXTURE DOME AS SHOWN FREE FROM FIXTURE SEE FITTER CAP DETAIL COMMON BLACK TO HOT AND GREEN TO G...

Страница 13: ...RELY INTO FITTER BALLAST INTO FITTER 5 SERVICE BALLAST 4 7 6 3 TURN POWER OFF BALLAST SERVICING 1 2 4 FITTER CAP DETAIL BALLAST SERVICING COMPLETE ROTATE FITTER CAP CLOCKWISE UNTIL TABS SNAP PLUG IN A...

Страница 14: ...LOCKWISE UNTIL BALLAST SERVICING COMPLETE UNPLUG ALL CONNECTORS AND REMOVE 2 SCREWS PLUG IN ALL CONNECTORS RE INSTALL BALLAST PULL LATCH AND LOWER FIXTURE TO ACCESS BALLAST FREE FROM FIXTURE SEE FITTE...

Страница 15: ...H AND LOWER FIXTURE TO ACCESS BALLAST FREE FROM FIXTURE SEE FITTER CAP DETAIL ROTATE FITTER CAP COUNTER CLOCKWISE UNTIL MOUNTING HARDWARE BY OTHERS MOUNTING SURFACE NOT FOR JUNCTION BOX PLACE WIRING I...

Отзывы: