MicroCore Upgrade Kit Installation Guide
Fixture: Universe Collection Medium (UCM) (HID to LED)
TM
www.aal.net
A R C H I T E C T U R A L A R E A L I G H T I N G
93046644 REV. D
PAGE 2/7
17760 ROWLAND ST. Tel(626)968-5666
CITY OF INDUSTRY Fax(626)968-5716
CALIFORNIA 91748
1.
REMOVE EXISTING REFLECTOR ASSEMBLY
TURN OFF ALL POWER TO
THE UNIT AND TAKE
PROPER SAFETY PRECAUTIONS.
FAILURE TO DO SO MAY RESULT
IN SERIOUS PERSONAL INJURY.
!
1. Open lower lens frame of the housing by
undoing (2) captive thumb screws located on
underside of fixture and swinging door frame
open as shown in Fig. 1-1 & Fig. 1-1A.
2. Allow door frame assembly to hang freely
as shown in Fig. 1-2
3. Remove existing reflector assembly by
prying housing from fixture. Existing reflector
assembly is held via ball socket studs as
shown in Fig. 1-3.
4.
Disconnect reflector assembly and set
aside as shown in Fig. 1-4
FIG. 1-1A
FIG. 1-1
FIG. 1-1A
FIG. 1-2
FIG. 1-3
FIG. 1-4
DOOR FRAME