O
PTIMA 32
15
Set the thermostat, if present, to the lowest level. Press slightly and turn the control
knob clockwise
3
to the
OFF
position and wait 5 minutes; thus allowing any gases
to escape which may have accumulated in the combustion chamber.
Note:
LP gases do not vent upward. Then follow step 2 and 3 to establish pilot.
OPERATION INSTRUCTIONS
Cont..
Press and turn control knob counterclockwise
4
to
ON
position.
Release knob. If pilot should go out, turn the control knob to
OFF
position and
repeat steps 1, 2 and 3.
Note:
The control valve is equipped with an internal safety interlock. You must
leave at “off” position for about 5 minutes before lighting pilot again.
Press slightly and turn control knob counterclockwise
4
to
PILOT
position;
depress control knob and light pilot by repeatedly pressing the sparker. Venting of
air may take place prior to flow of pilot gases. Once flame is established, hold knob
depressed for approximately 30 seconds.
MILLI-VOLT VALVE START-UP PROCEDURE
1.
2.
3.
4.
5.
7.
Turn flame and heat adjustment knob to the desired comfort level from
HI
GH to
LO
W.
8.
SHUT-DOWN PROCEDURE TO PILOT FLAME
To turn off the main burner only, set the thermostat to the lowest setting or turn
switch to OFF. Press and turn the knob clockwise
3
to
PILOT
position.
Press and turn the knob clockwise
3
to the
OFF
position.
COMPLETE SHUT-DOWN PROCEDURE
6.
Turn thermostat to the desired comfort level or turn ON/OFF switch to the ON position.
Sparker
Control Knob
Flame and Heat Adjustment Knob
Pilot Adjustment Screw
Control indicator
Attach on-off
switch leads
here