Archgard Optima 32 Скачать руководство пользователя страница 1

OPTIMA 32

 

 

Gas Fired Vented Room 
Heater (Direct Vent) 

7116 Beatty Dr 
Mission, BC V2V 6B4 
Canada 

For use with natural gas or 

propane 

 Installer: Please leave this manual with the appliance owner for future reference 

U

SERS 

 

I

NSTALLATION 

 

 

O

PERATION &    
 

M

AINTENANCE 

 

 

 

M

ANUAL 

— Do not store or use gasoline or other flammable  
 

vapors and liquids in the vicinity of this or any 
other appliance. 

 

 WHAT TO DO IF YOU SMELL GAS

 

·  Do not try to light any appliance. 
·  Do not touch any electrical switch; do not use 

any phone in your building. 

·  Immediately call your gas supplier from a  
  neighbor’s phone. Follow the gas supplier’s  
 instructions. 
·  If you cannot reach your gas supplier, call the 

fire department. 

— Installation and service must be performed by a  
 

qualified installer, service agency or the gas 
supplier. 

200-0100 
 
04 Oct 02 

WARNING:

 

If the information in this manual is 

not followed exactly, fire or explosion may result 
causing property damage, personal injury or loss 
of life. 

This appliance may be installed in an 
aftermarket permanently located, 
manufactured home (USA only or mo-
bile home, where not prohibited by lo-
cal codes. 
 
This appliance is only for use with the 
type of gas indicated on the rating 
plate. This appliance is not convertible 
for use with other gases, unless a certi-
fied kit is used. 

U

Master Contract:  214018 

f i r e - p a r t s . c o m

Содержание Optima 32

Страница 1: ...hbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or...

Страница 2: ...hould be carefully supervised when they are in the same room as the appliance Clothing or other flammable material should not be placed on or near the appliance Do not operate with cracked or broken g...

Страница 3: ...wner s liking and heating needs Solid Construction The Optima 32 is constructed mainly of 16 and 18 gauge galvanized and aluminized coated steel for long life and durability Optional Decorative Check...

Страница 4: ...code ANSI NFPA No 70 1987 in the US and in Canada the current Canadian Electrical Code CSA C22 1 HIGH ALTITUDE INSTALLATION When installing this appliance beyond 4500 ft 1372 m above sea level The ap...

Страница 5: ...32 5 APPLIANCE DESCRIPTION TOP VIEW FRONT VIEW LOG SET BRICK PANELS BOTTOM GRILL GLASS DOOR TOP GRILL INLET FLUE CONNECTION ON OFF SWITCH POWER CORD AND GAS INLET SIDE OUTLET FLUE CONNECTION fire par...

Страница 6: ...round Flue Collar inlet 3 76 mm diameter Flue Collar outlet 3 76 mm diameter DIMENSIONS AND CLEARANCES MINIMUM FIREPLACE DIMENSIONS 16 1 2 419 mm 27 685 mm 15 3 4 400 mm 20 508 mm SIDE VIEW TOP VIEW A...

Страница 7: ...OPTIMA 32 7 DIMENSIONS AND CLEARANCES Cont fire parts com...

Страница 8: ...he gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Failure to do so will damage the appliance s gas valve Such damage is not covered by the manufacturer s warranty Na...

Страница 9: ...ack supply conductor to the free black conductor from the speed controller with a marrette type wire connector Connect the neutral white supply conductor to the free white conductor from the convectio...

Страница 10: ...the appliance flue collars to the termination cap If you are using the Dura vent vertical termination cap follow the instructions provided with these components CAUTION To ensure that the venting pat...

Страница 11: ...ches underneath the door Lift out the bottom of the door and lift the whole door assembly up and off the two locating tabs at the top of the door assembly Replacing the Glass Door The reverse procedur...

Страница 12: ...A small bag of embers and coals are provided with the fireplace Carefully place the embers and coals on the tray between the grate and the burner Try not to allow the embers to obstruct the burner po...

Страница 13: ...t over the extension knobs move the rear bend over the bottom bend of the heater and insert the left side in front of the Fan Control Bracket 9 Line up the corresponding mounting holes see Fig 2 and t...

Страница 14: ...door and faceplate are properly attached and fastened Do not operate this appliance with broken cracked glass doors or without the door s in its correct and latched position Do not use abuse the glass...

Страница 15: ...ontrol knob counterclockwise 4to PILOT position depress control knob and light pilot by repeatedly pressing the sparker Venting of air may take place prior to flow of pilot gases Once flame is establi...

Страница 16: ...eak them Do not wash logs with any liquid While the logs are removed also remove the coals or embers and check that all burner openings are no obstructed and it is recommended you use a vacuum cleaner...

Страница 17: ...will not remain on after being lit 1 Press the control knob all the way in at the pilot indicator 2 Hold the control knob in for a longer period of time 3 If you are trying to re light the pilot immed...

Страница 18: ...1 If the flame is yellow and lazy check for lint etc around pri mary air shutter Increase primary air by opening the primary air shutter if necessary 2 Check for proper placement of the logs and branc...

Страница 19: ...PEED CONTROL LINE CONVECTION BLOWER GROUND 110F 43 C N O THERMAL SNAP SWITCH NEUTRAL ELECTRICAL BOX 120 VAC PILOT ASSEMBLY ON OFF SWITCH OPTIONAL THERMOSTAT THERMOPILE SPARK ELECTRODE THERMOCOUPLE PIL...

Страница 20: ...et at the factory and normally only requires resetting at higher altitudes Open the lower grills Unscrew the 2 screws holding the control panel and remove the panel The primary air adjustment wing nut...

Страница 21: ...ve the characteristic as shown in the illustration below The flame should not have yellow tips but should engulf the thermocouple and thermopile It can be ad justed be turning the screw marked pilot o...

Страница 22: ...ACING CONVECTION BLOWER SHOULD YOUR GLASS BREAK In the event your glass cracks or breaks it must be replaced by the exact same size and mate rial The glass is made from high temperature ceramic materi...

Страница 23: ...ed at the bottom of the appliance at the back Remove the three screws holding the blower Lift the blower out and disconnect the wires from the blower Disassembly picture step 1 Remove the H burner fro...

Страница 24: ...Valve 308 0094 1 Honeywell Knob Extension HI LO 308 0095 1 Honeywell Knob Extension ON OFF 308 0096 1 Honeywell Piezo Knob Extension 308 0093 1 PSE Conv Pilot Assembly NG LP Base Mount 310 0009 1 Bag...

Страница 25: ...if in doubt OBTAINING WARRANTY SERVICE To obtain warranty service the consumer shall return the defective part to the original selling dealer transportation prepaid along with the serial number of the...

Страница 26: ..._________________ _____________________________________________________________ Dealer s Name Address ______________________________________________________ ___________________________________________...