LOG PLACEMENT   

WARNING

Failure to position the parts in accordance with these diagrams or failure to use only parts  
specifically approved with this appliance may result in property damage or personal injury. 

The Archgard pan burner bed and fiber logs are designed to give a realistic fire package, and 
created to look the same as the day they were originally installed. Care must be given when 
first installing the logs, and if removed for servicing, as they can be damaged or broken if not 
handled properly.  
 
After opening the log set package, inspect the logs to ensure that no damage has occurred 
inside the package. Please report any damage immediately to your Authorized Archgard 
Dealer.  
 
Gas and vent connection must be made before installing the embers and logs on the pan 
burner.

 

NOTE

: Improper placement of logs and embers may cause soot accumulation on the internal 

parts and glass. This is not covered under warranty. Do not use broken or damaged logs.  

Locate the embers and logs and place them on their prospective locations. Refer to the pictured 
instructions on the following pages that will show how to place all seven (7) logs.  Pins and holes 
must be aligned with logs and burner. 
 

IMPORTANT

: Embers should be placed so as not to completely block burner ports.  Separate 

the material and spread around the pan.   

NOTE:  

Installing the fiber logs in any other position other than shown will result in flame 

impingement causing sooting of the logs, brick liner and ceramic glass viewing area. 

Locator Pins 

 

LOCATOR PINS 

BURNER AIR TRAY 

Содержание 31-DVIE33

Страница 1: ...sion kit required for Propane use Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any...

Страница 2: ...gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the instal lation unless upon inspection the inspector observes carbon monoxide detectors and signage installe...

Страница 3: ...s less expensive to operate Adjustable Fan Speed Each 31 DVIE33 comes complete with 6 level adjustable speed controlled circulation fan Adjustable Flame The flame aesthetics and heat output can be adj...

Страница 4: ...ctions 16 17 Restrictor Plate Surround Installation and Rocker Switch Wiring 18 Log Placement 19 24 Glass Door Removal If Your Glass Should Break 25 Final Installation Check and Initial Operation 26 F...

Страница 5: ...and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding materials etc It is imperative that the control compartments...

Страница 6: ...code ANSI NFPA No 70 1987 in the US and in Canada the current Canadian Electrical Code CSA C22 1 We recommend that our gas hearth products be installed and serviced by professionals who are certified...

Страница 7: ...filters Certified for use in both CANADA and USA Certifi pour utilisation dans le Canada et les TATS UNIS VENTED GAS FIREPLACE HEATER NOT FOR USE WITH SOLID FUEL DO NOT REMOVE THIS LABEL NE PAS ENLEVE...

Страница 8: ...s Out configuration by removing the two mounting screw on each side and swinging the panels out and replacing the screws They can also be disconnected and placed remotely within the limits of the gas...

Страница 9: ...uilt fireplace has no gas access hole s provided an access hole of 1 1 2 38 1 mm or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner This access...

Страница 10: ...y metal parts is prohibited except the metal floor J as specified The metal floor of the firebox may be removed only if the following is strictly adhered to The metal floor J may be removed to allow a...

Страница 11: ...tension maybe increased 1 25 4 mm for each additional 1 25 4 mm increase in clearance height Example If using a 5 127 mm reduce minimum height to 31 788 mm If using a 4 102 mm reduce minimum height to...

Страница 12: ...individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Failure to do so will damage the appliance s gas v...

Страница 13: ...ction for proper de rating methods PREPARE THE FIREPLACE Remove the surround glass frame assembly logs and brick if applicable Remove the burner air tray by removing the two screws at the back wall an...

Страница 14: ...velope top of the flame sensor and extend forward onto the burner To adjust pilot turn the pilot adjustment screw on the control valve clockwise to decrease or counter clockwise to increase pilot flam...

Страница 15: ...rd Do not cut or remove the grounding prong from this plug NOTE This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the Nat...

Страница 16: ...rminals are to be used for this appliance A T T E N T I O N NO OTHER VENTING SYSTEM OR COMPONENTS MAY BE USED Follow manufacturer instructions for installation of termination This appliance is designe...

Страница 17: ...ictors provided with the unit if required Seal and attach the end of the flex marked Exhaust to the collar marked Exhaust on the appliance 9 Caulk all joints using a high temperature sealant such as m...

Страница 18: ...of the trim Now fully seat the unit into its final position Surround Mounting slots Surround Mounting tabs Main On Off switch must be connected to the surround switch and in the on position for the r...

Страница 19: ...our Authorized Archgard Dealer Gas and vent connection must be made before installing the embers and logs on the pan burner NOTE Improper placement of logs and embers may cause soot accumulation on th...

Страница 20: ...ty Unit 310 634720 1 Log 1 Left Rear 1 EA 310 634720 2 Log 2 Right Mid 1 EA 310 634720 3 Log 3 Left Mid 1 EA 310 634720 4 Log 4 Right 1 EA 310 634720 5 Log 5 Left Top 1 EA 310 634720 6 Log 6 Front Cro...

Страница 21: ...k shelf and to the left so it is almost touching Log 1 Force the log down onto the locater pins NOTE There are no holes in Log 7 must use gentle force Step 1 Locate Log 1 and align the holes in the bo...

Страница 22: ...n the two holes in the log with the two locater pins on the left of the burner Push down onto locator pins as shown Step 4 Locate Log 2 and align the two holes in the log with the two locater pins on...

Страница 23: ...e hole in the bottom with the pin in log 3 Place the other end of the log in the saddle of log 1 LOG 5 Step 6 Locate Log 6 and align the hole in the bottom with the locater pin in log 3 Place the othe...

Страница 24: ...tom with the pin on the burner surround tray Place the other end onto log 2 as shown LOG 4 Step 8 Place black embers around logs as shown do not block the holes in the burner Maintain a 1 4 clearance...

Страница 25: ...he door to ensure the door is seated all the way down on the catches 7 Pull the finger rings out and down to engage in the slots on the top of the door frame 8 Push the finger rings back in IF YOUR GL...

Страница 26: ...tly and that the electrical system is in working order This will include 1 Perform leak tests of supply line gas control valve supply line from gas control valve and pilot assembly 2 Clocking the appl...

Страница 27: ...sted directly above or as shown on the front cover of this manual 3 Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance...

Страница 28: ...31 DVIE33 28 LIGHTING INSTRUCTIONS ON RATING PLATE...

Страница 29: ...31 DVIE33 29 REMOTE CONTROL SETUP AND OPERATION NA on this unit Future option...

Страница 30: ...31 DVIE33 30 REMOTE CONTROL SETUP AND OPERATION cont future option N A on this unit...

Страница 31: ...31 DVIE33 31 REMOTE CONTROL SETUP AND OPERATION cont...

Страница 32: ...31 DVIE33 32 REMOTE CONTROL SETUP AND OPERATION cont Note When the fireplace is started in Smart Thermostat mode the fan will come on 5min after ignition and shut down 12min after fire is turned off...

Страница 33: ...31 DVIE33 33 REMOTE CONTROL SETUP AND OPERATION cont Note When the fireplace is started in Smart Thermostat mode the fan will come on 5min after ignition and shut down 12min after fire is turned off...

Страница 34: ...Adjust the fan speed to personal preference Blower will shut off when the burner is extinguished The unit is shipped from the factory with the ability for IPI CPI selection active To disable the Conti...

Страница 35: ...31 DVIE33 35 REMOTE CONTROL SETUP AND OPERATION cont...

Страница 36: ...o clean off any dust or lint After cleaning the logs and embers must be replaced as per the instructions in this manual Once a year have a qualified service technician Completely inspect the appliance...

Страница 37: ...ment The right side shows yellow sooty flames requiring increase in shutter opening or cleaning of shutter area due to lint buildup WARNING Servicing of this appliance must be conducted by a qualified...

Страница 38: ...he readings obtained are within specs as shown on the appliance rating plate 6 Be sure to tighten the set screw inside the tap after you have finished taking pressure readings 7 Check for leaks CHECKI...

Страница 39: ...L instructions within this manual 2 Remove the log set Follow LOG PLACEMENT instructions within this manual 3 Remove the pan burner Follow instructions for CHANGING MAIN BURNER ORIFICE within the conv...

Страница 40: ...31 DVIE33 40 WIRING SCHEMATICS Main On Off switch must be connected to the surround switch and in the on position for the remote to operate the fireplace Synchronization button...

Страница 41: ...anual If you cannot solve the problem contact your Archgard Dealer or representative When calling for help please have the following information Model of your Fireplace Serial Number Place of Purchase...

Страница 42: ...witch closes the electrical circuit that allows the fan to turn on This is a normal sound Q I hear a ticking cracking or pinging sound when my fireplace is running and after it is turned off A The dif...

Страница 43: ...31 DVIE33 43...

Страница 44: ...EA 301 0068 Orifice Main Burner Orifice Drill to 33 DMS for Natural Gas EA Orifice Main Burner Orifice Drill to 51 for LP Propane Gas EA 308 0123 Pilot Assembly conv PSE IPI SIT connections EA 831 005...

Страница 45: ...31 DVIE33 45 NOTES...

Страница 46: ...ame Address City State Prov ZIP Phone _____ Why did you choose this product Thank you for purchasing our product and filling out this warranty card mm dd yyyy POSTAGE FOLD DOWN AT LINE FOLD DOWN AT LI...

Страница 47: ...31 DVIE33 47...

Страница 48: ...Archgard Industries Ltd 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...

Отзывы: