STEP 3 

Using the "Z" dimension as described in step 2, use the string and chalk to draw an 
arc (with radius of "Z") to define the area for cutting the mounting holes on the 
chute wall. 

 
 
STEP 4 

From the centerline of the head pulley measure down approximately 12”

 

(304.8mm) (See Figure 1. Dimension "B").  This is the highest point that the 
cleaner should be mounted. It can be mounted anywhere along the radius that was 
marked off in step 3.  The limiting factor is the restriction of a dribble chute or lack 
of a dribble chute at the point where the belt leaves the head pulley on the return 
side.  

Note: DO NOT install the cleaner within the trajectory of the material. 

 
 

STEP 5

 

After you have located the correct position to mount the cleaner, mark two oval 
shaped holes approximately 3 ½”

 

(88.9mm) x 4 ½” (114.3mm) in size.  These 

should now be torched or cut out.  

NOTE:

 

DO NOT USE EXISTING HOLES FROM 

ANOTHER BRAND OF CLEANER. 

 

 

 

 
 
 
STEP 6 

Disassemble the cleaner.  This is done by removing the pin on the tensioner (Item 
2) at the end of the tensioner hub.  Remove the tensioner (Item 2) from the 
tensioner pipe (Item 1). You will find the tensioner wrench inside the tensioner 
pipe.  Loosen the set screws on the mainframe to allow  removal of the pipes.

 

 
 

 

 