- 2 -
- 3 -
1.3 Adaptor specification
No.
Item
Input Signal / Load
Unit
Limit
Result
DC OUT/V
Unload 23ohm
1.31 DC OUTPUT
90
V
15.0±5%
120
230
264
1.32 Ripple and Noise 10uF electrolytic cap, 0.1uF ceramic cap load &
23 ohm load
Measure by 20M bandwidth oscilloscope
mVp-p
100
1.4. Charging
Blue LED is on when iPod is inserted, press button to initiate charging. The red LED is then on.
1.5. ESD
+ / - 4KV, 330 ohm, 150pF for direct contact
+ / - 8KV, 330 ohm, 150pF for air contact
1.6. RS232 connection with Solo One Box/Mini Solo
This cable is actually used for the communication of rDock (iPod is here) with all Arcam Solo models.
Test equipment:
a. Cable
1000+/-20
b. iPod Communication
- Connect the cable to rDock and PC
- Open the software “iPod Communication”